CT-Referenced Diagnostic Performance and Complementary Error Patterns of Artificial Intelligence Versus a Single Emergency Physician in Chest Radiograph Interpretation: A Retrospective Paired Diagnostic Accuracy Study.
Ömer Damar, Mahmut Yaman
Department of Emergency Medicine, Faculty of Medicine, Mardin Artuklu University, 47200 Mardin, Türkiye. · Department of Emergency Medicine, Faculty of Medicine, Dicle University, 21280 Diyarbakır, Türkiye.
Key points
From the paper's conclusion- The findings support prospective multireader evaluation of AI as a second-reader tool but do not establish benefit from real-time AI-assisted interpretation.
Abstract
Background/Objectives: Artificial intelligence (AI) is increasingly used to support chest radiograph interpretation, but its clinical value depends not only on stand-alone accuracy but also on whether its errors differ from those of clinicians. We evaluated CT-referenced, target-specific diagnostic performance and complementary error patterns of a commercial chest radiograph AI system and a single emergency physician. Methods: In this retrospective, single-center, paired diagnostic accuracy study, 920 consecutive adults who underwent posteroanterior chest radiography and thoracic computed tomography (CT) within 4 h during the same emergency department encounter were included. A commercial AI system (hChestXR version 1) and a single blinded emergency physician independently assessed eight prespecified thoracic findings using CT as the reference standard. Paired differences were estimated with 10,000 patient-level bootstrap resamples and tested with exact McNemar tests with Holm adjustment. Exact-target complementarity and simulated same-target OR/AND rules were secondary exploratory analyses. Results: Across 7360 patient-target assessments, including 1232 CT-positive findings, AI had significantly greater Holm-adjusted sensitivity for pneumothorax (90.8% vs. 50.8%), nodule/mass (63.3% vs. 32.7%), and rib fracture (77.2% vs. 46.5%). AI-only detections were most frequent for pneumothorax (47.7%), nodule/mass (44.9%), and rib fracture (43.6%), whereas physician-only detections were most frequent for atelectasis (24.8%), pulmonary edema (21.0%), and lung opacity (19.7%). In exploratory pooled analyses, sensitivity was 73.0% for AI and 62.0% for the physician. Exploratory simulated same-target OR/AND analyses demonstrated a sensitivity-specificity trade-off across pooled patient-target assessments but did not represent observed AI-assisted clinical performance. Conclusions: The AI system and the single emergency-physician reader in the study showed target-dependent, partly non-overlapping error patterns in this CT-selected emergency cohort. The findings support prospective multireader evaluation of AI as a second-reader tool but do not establish benefit from real-time AI-assisted interpretation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Default-threshold operating-point validation of a commercial chest radiograph AI system for selected CT-anchored thoracic findings: a bi-national multicenter retrospective study.Scientific reports · 2026
- Diagnostic Performance of Different AI Tools for Chest Radiography: A CT-Anchored Per-Abnormality Analysis in a Tertiary Referral Center.Diagnostics (Basel, Switzerland) · 2026
- Prospective Diagnostic Accuracy and Technical Feasibility of Artificial Intelligence-Assisted Rib Fracture Detection on Chest Radiographs: Observational StudyJMIR Medical Informatics · 2026
- Artificial intelligence and the phantom pneumothorax: Clinical reasoning still matters.Emergency radiology · 2026
- Novel Artificial Intelligence Chest X-ray Diagnostics: A Quality Assessment of Their Agreement with Human Doctors in Clinical RoutineRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · 2026
- A DeepSeek-powered AI system for automated chest radiograph interpretation in clinical practiceNature Communications · 2026