Novel Artificial Intelligence Chest X-ray Diagnostics: A Quality Assessment of Their Agreement with Human Doctors in Clinical Routine
Wolfram A. Bosbach, Luca Schoeni, Jan F. Senge, Milena Mitrakovic, Marc-André Weber, Pawel Dlotko, Keivan Daneshvar
University of Bern · University of Bremen
Key points
From the paper's conclusion- Novel Artificial Intelligence Chest X-ray Diagnostics: A Quality Assessment of Their Agreement with Human Doctors in Clinical Routine.
Abstract
Purpose: The rising demand for radiology services calls for innovative solutions to sustain diagnostic quality and efficiency. This study evaluated the diagnostic agreement between two commercially available artificial intelligence (AI) chest X-ray systems and human radiologists during routine clinical practice. Materials and Methods: We retrospectively analyzed 279 chest X-rays (204 standing, 63 supine, 12 sitting) from a Swiss university hospital. Seven thoracic pathologies - cardiomegaly, consolidation, mediastinal mass, nodule, pleural effusion, pneumothorax, and pulmonary oedema - were assessed. Radiologists' routine reports were compared against Rayvolve (AZmed) and ChestView (Gleamer, both from Paris, France). A Python code, provided as open access supplement, calculated performance metrics, agreement measures, and effect size quantification. Results: Agreement between radiologists and AI ranged from moderate to almost perfect: Human-AZmed (Gwet's AC1: 0.47-0.72, moderate to substantial), and Human-Gleamer (Gwet's AC1: 0.56-0.96, moderate to almost perfect). Balanced accuracies ranged from 0.67-0.85 for Human-AZmed and 0.71-0.85 for Human-Gleamer, with peak performance for pleural effusion (0.85 both systems). Specificity consistently exceeded sensitivity across pathologies (0.70-0.98 vs 0.45-0.85). Common findings showed strong performance, pleural effusion (MCC 0.70-0.73), cardiomegaly (MCC 0.51), and consolidation (MCC 0.45-0.46). Rare pathologies demonstrated lower agreement, mediastinal mass, and nodules (MCC 0.23-0.31). Standing radiographs yielded superior agreement compared to supine studies. The two AI systems showed substantial inter-system agreement for consolidation and pleural effusion (balanced accuracy 0.81-0.84). Conclusion: Both commercial AI chest X-ray systems demonstrated comparable performance to human radiologists for common thoracic pathologies, with no meaningful differences between platforms. Performance was strongest for standing radiographs but declined for rare findings and supine studies. Position-dependent variability and reduced sensitivity for uncommon pathologies underscore the continued need for human oversight in clinical practice. Key Points: · AI systems matched radiologists for common chest X-ray findings.. · Standing radiographs achieved the highest diagnostic agreement.. · Rare pathologies showed weaker AI-human agreement.. · Supine studies reduced diagnostic performance.. · Human oversight remains essential in clinical practice.. Citation Format: · Bosbach WA, Schoeni L, Senge JF et al. Novel Artificial Intelligence Chest X-ray Diagnostics: A Quality Assessment of Their Agreement with Human Doctors in Clinical Routine. Rofo 2025; DOI 10.1055/a-2778-3892.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Independent Head-to-Head Comparison of Commercial Artificial Intelligence Devices for Lung Cancer Detection on Chest RadiographsRadiology · 2026
- CT-Referenced Diagnostic Performance and Complementary Error Patterns of Artificial Intelligence Versus a Single Emergency Physician in Chest Radiograph Interpretation: A Retrospective Paired Diagnostic Accuracy Study.Tomography (Ann Arbor, Mich.) · 2026
- A DeepSeek-powered AI system for automated chest radiograph interpretation in clinical practiceNature Communications · 2026
- Benchmarking of AI and Radiologists for Indeterminate Lung Nodule Malignancy Risk Estimation at Screening CT: The LUNA25 ChallengeRadiology Artificial Intelligence · 2026
- Default-threshold operating-point validation of a commercial chest radiograph AI system for selected CT-anchored thoracic findings: a bi-national multicenter retrospective study.Scientific reports · 2026
- Multi-agent AI system for radiology report structuring and quality assurance with independent radiologist evaluationFrontiers in Radiology · 2026