Technical Review: Performance, Design, and Deployment of Steel Helical Pile Groups for Transmission Infrastructure
Fereshteh Ghorbani Anilou, Pooria Pasbakhsh, Zipeng Zhang, Brodie Houghton, Kevin Otto
Key points
From the paper's conclusion- These findings indicate that helical piles are a resilient, logistically efficient alternative to bored piles for much of Australia’s transmission foundation demand when applied on a site-specific basis, and the review recommends Australian design guidance and further grounding-performance research.
Abstract
Worldwide transmission-grid expansion requires extensive construction of new tower foundations across diverse geological, environmental, and logistical conditions, while conventional bored piling faces increasing cost, schedule, constructability, and adaptability constraints. Steel helical pile groups have been proposed as an alternative, but a systematic evaluation of their suitability for Australian transmission infrastructure has been lacking. This narrative review synthesizes Australian and international case studies, current design standards, and published installation-productivity models to compare helical and bored piles on installation logistics, quality assurance, structural and lateral load performance, environmental footprint, and the under-examined implications of foundation type on tower earthing and lightning performance. The comparison finds that helical piles offer real-time, torque-based capacity verification, immediate load-bearing capacity, and lower labor intensity under favorable ground conditions. However, shallow competent bedrock, dense gravels or boulder-affected ground, and very high lateral-load structures favor bored piles or hybrid solutions, and helical-pile grounding performance for tower earthing has not yet been independently verified. These findings indicate that helical piles are a resilient, logistically efficient alternative to bored piles for much of Australia’s transmission foundation demand when applied on a site-specific basis, and the review recommends Australian design guidance and further grounding-performance research.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- In Situ Tests and Numerical Simulation Study on the Tensile Bearing Capacity of Large-Anchor-Plate Helical Anchors for 500 kV Transmission TowersBuildings · 2026
- Study of mechanical characteristics of prefabricated anchor rod foundation based on full-scale testJournal of Physics: Conference Series · 2026
- Analysis of grounding characteristics of single-direction extended auxiliary grounding grids for transmission towersJournal of Physics: Conference Series · 2026
- Analysis of the Implementation of Effective Grounding in 400 kV Overhead LinesEnergies · 2026
- Optimization of lightning protection grounding devices for distribution line towers under limited construction areaJournal of Physics: Conference Series · 2026
- A generalised soil–structure interaction model for circular plates on piles under vertical eccentric loadGéotechnique · 2026