A Finite-State and Boolean Control Framework for Resilient Power and Thermal Management in Telecommunication Base Stations
Emmanuel Ahatsi, Oludolapo Olanrewaju
Key points
From the paper's conclusion- The framework is exercised through eleven structured operating and fault scenarios and summarized in a nine-property formal verification table that distinguishes properties satisfied by construction (source exclusivity, generator lockout, thermal-threshold activation) from properties the source design leaves unresolved (partial-phase-loss continuity, thermostat-interrupt exit behaviour, and alarm/
Abstract
Telecommunication base transceiver stations (BTS) require power-source switching and thermal-management logic that remains predictable and checkable under grid disturbances, generator operation and thermal excursions. Existing microcontroller-based BTS site-management implementations, including the ATmega32-based MBSMECS architecture that motivates this study, provide the basis for the present formal analysis, describe this logic operationally as narrative relay behaviour rather than as an explicit verifiable control model. This paper reformulates the switching and thermal-control logic of that implemented system as a two-layer formal control framework: a finite-state model that represents grid-supply, generator-start-permissive, generator-supply, restoration, transfer and shutdown conditions as explicit states and transition conditions and a Boolean interlock layer that expresses three-phase grid availability, the generator-start permissive and source exclusivity as logical expressions. A symbolic lumped-parameter thermal model with hysteresis switching is developed to represent the thermostat-driven air-conditioner allocation logic and is treated as a discrete-event process coupled to, rather than separate from, the power-switching automaton. Component-level sizing calculations from the original design are retained as supporting engineering-consistency checks rather than as the paper’s central contribution. The framework is exercised through eleven structured operating and fault scenarios and summarized in a nine-property formal verification table that distinguishes properties satisfied by construction (source exclusivity, generator lockout, thermal-threshold activation) from properties the source design leaves unresolved (partial-phase-loss continuity, thermostat-interrupt exit behaviour, and alarm/thermal concurrency). No new experimental or simulated hardware data are introduced; all quantitative illustrations are explicitly labelled as hypothetical. The contribution is a transparent and reusable formal representation of the switching and thermal-control logic, distinct from the underlying hardware implementation that supports design review, verification and future extension of this class of BTS control system.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Dynamic Model and Stability Analysis of a Grid-Interactive Data CenterarXiv · 2026
- Voltage Ride-Through-Constrained Power Capping for Large-Scale Data CentersarXiv · 2026
- Feeder-Aware Service-Conditioned Flexibility of Grid-Interactive BuildingsarXiv · 2026
- DC-TORQ: Fast Assessment of Data Center-Induced Generator Torsional Oscillation Risk QuantificationarXiv · 2026
- Assessing Data Center Hosting Capacity Considering Electromagnetic Transient DynamicsarXiv · 2026
- Transferable Neuromorphic Protection for Distribution NetworksarXiv · 2026