Coordinated Transient Voltage Support Considering Induction Motor Dynamics in PV-Integrated Distribution Networks Under Symmetrical Faults
Tao Zhou, Wenxiang Xu, Yichen Zhou, Yi Wang, Cheng Wang
Key points
From the paper's conclusion- During symmetrical faults in photovoltaic (PV)-integrated distribution networks, induction motor (IM) deceleration elevates reactive-power demand and delays post-fault voltage recovery, whereas conventional voltage-driven support can withdraw prematurely upon initial voltage rebound.
Abstract
During symmetrical faults in photovoltaic (PV)-integrated distribution networks, induction motor (IM) deceleration elevates reactive-power demand and delays post-fault voltage recovery, whereas conventional voltage-driven support can withdraw prematurely upon initial voltage rebound. To resolve this mismatch, this paper proposes a coordinated transient voltage support (CTVS) strategy that explicitly incorporates IM electromechanical dynamics. A coupled differential-algebraic equation (DAE) model integrating third-order IM dynamics, distributed PV (DPV) DC-link dynamics, and network power balance is formulated, from which a trajectory-local closed-loop Q–V sensitivity is derived to characterize location-dependent support effectiveness. The CTVS controller coordinates critical-bus voltage magnitude, voltage-decrease rate, and rotor slip through fixed spatial participation coefficients under local converter current limits and DC-link voltage feedback. Case studies on a modified IEEE 33-bus feeder under Bus-32 three-phase faults demonstrate that, for the representative 140 ms fault, CTVS suppresses post-fault secondary voltage depression and reduces the sustained recovery delay to 23.85 ms, compared with 342.30 ms for local low-voltage ride-through and 390.85 ms for adaptive Q–V droop control. Matched ablations identify slip-conditioned support persistence as the principal contributor to sustained voltage recovery, whereas the fixed spatial coefficients provide a local allocation advantage under unsaturated conditions rather than a separate large-disturbance recovery benefit under the tested conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fault Response Regulation Model and Voltage Support Strategy for Inverter‐Interfaced Distributed Generator During Asymmetrical FaultsIEEJ Transactions on Electrical and Electronic Engineering · 2026
- Phase-Coordinate Modeling of Electromagnetic Transients for Fault Analysis in Distribution NetworksElectronics · 2026
- Modeling of Induction Motor Response to Voltage Sags with Re-Acceleration AnalysisEnergies · 2025
- Fault Detection with Weak Electrical Signatures in Grid-Connected Distributed PV Systems Using Positive-to-Negative-Sequence Perturbation ResponsesElectronics · 2026
- Dynamic active torque coordination strategy for torsional vibration suppression in wind turbines during grid fault recoveryInternational Journal of Electrical Power & Energy Systems · 2026
- Voltage Support Capability Analysis for Grid-Forming Inverters With Adaptive Virtual Impedance Under Asymmetrical Grid FaultsIEEE Transactions on Industrial Electronics · 2025