The Investigation of Fault Behaviors and Locations in Hybrid Multiterminal HVDC System Integrated with Renewable Energy Sources
Olumoroti Ikotun, Evans Eshiemogie Ojo, Musasa Kabeya
Key points
From the paper's conclusion- The findings indicated that during the scenario of an 8 ohms of resistance under a single line to ground fault, phase A of the inverter AC grid voltage decreased from its operational level.
Abstract
The study of hybrid multiterminal high-voltage direct current (HVDC) systems revealed different outcomes regarding their performance under fault conditions. Previous research showed that under the fault conditions, the high-voltage direct current (HVDC) voltage experienced a drop to zero, accompanied by a reverse overshoot. In this paper, a model that integrates hybrid multiterminal line commutated converters (LCCs) and a voltage source converter (VSC) with an HVDC network is presented. The model has been mathematically formulated and implemented using Matlab/Simulink (R2018b) software to examine its fault behaviors and locations, particularly on the DC line to ground fault, line to line fault, and single line to ground fault across various fault resistance levels. The system consists of a wind energy conversion system, a photovoltaic array, protection scheme, LCC rectifier station, VSC inverter station, inverter control, AC filters, a distributed parameter transmission line for the HVDC transmission line, a three-phase inductor-capacitor (LC) filter, and a three-phase transformer. The findings indicated that during the scenario of an 8 ohms of resistance under a single line to ground fault, phase A of the inverter AC grid voltage decreased from its operational level. Meanwhile, the voltage across the DC line increased, accompanied by a rise in DC line current. Additionally, calculations of the fault location were determined to be 1.1561 km from the point of reference. This study contributes to the understanding of fault dynamics in HVDC systems, providing essential insights that enhance operational reliability and efficiency in power transmission networks.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Single-End Line Protection of Hybrid HVDC System Based on Boundary Characteristic Frequency Band Energy RatioIEEE Transactions on Industrial Electronics · 2026
- Design of a comprehensive protection algorithm for fault detection, classification, and location in high voltage direct current transmission lines connected to wind farms based on local terminal measurements.PloS one · 2026
- System-Level Optimization of Hybrid Diode–Thyristor Fault Current Limiters for Multi-Terminal HVDC ProtectionEnergies · 2026
- Enhancing stability in renewable energy transmission using multi-terminal HVDC systems with grid-forming controls for offshore and onshore wind integrationScientific Reports · 2025
- Rapid identification method of commutation failure risk areas in HC-HVDC systems under single-phase faultsInternational Journal of Electrical Power & Energy Systems · 2025
- Architectural Vulnerability Mapping and Analysis in Hybrid AC/DC Distribution NetworksEnergies · 2026