Enhancing stability in renewable energy transmission using multi-terminal HVDC systems with grid-forming controls for offshore and onshore wind integration
Abu Shufian, Md Ismail Hossain, Hasanur Zaman Anonto, Ahmed Intekhab Rohan
American International University-Bangladesh · Islamic University of Technology
Key points
From the paper's conclusion- The results demonstrated the GFM controller's capability to stabilize power systems rapidly and fulfill grid code requirements even in the presence of compounded disturbances.
Abstract
This paper presents a thorough analysis of two-terminal VSC-HVDC links, and the effects of isolated faults have been extensively studied in multi-terminal HVDC (MTHVDC) networks systems that would enable the interconnection of substantial offshore wind farm energy resources to onshore power systems with emphasis on dynamic transmission performance during different fault and perturbation scenarios. The performance of the system was evaluated against three important scenarios: transient faults, sudden load drops, and wind speed changes. The work presented a comparative analysis of Grid-Following (GFL) and Grid-Forming (GFM) control strategies with a focus on their provisions in offering compliance with grid code requirements, particularly, in faults ride-through (FRT) performance. Transient stability and grid compliance has been performed through the study to take results as the GFM controller performance has been better as compared to GFL controller in the study. The GFM controller recovered more rapidly than its GFL counterpart, achieving voltage stability within 0.5 s and frequency stability within 0.6 s when subjected to fault and load disturbances, versus 1.2 s and 1.8 s for the GFL controller's voltage and frequency, respectively. The difference in voltage and frequency deviation between the GFL and the GFM system was less than ± 4% and less than ± 0.3 Hz respectively, further verifying that the GFM system far outperformed the GFL system, which demonstrated a voltage stability of ±18% and a frequency stability of ± 0.9 Hz under load disturbance. The results demonstrated the GFM controller's capability to stabilize power systems rapidly and fulfill grid code requirements even in the presence of compounded disturbances. The virtual inertia and dynamic dampness provided by GFM controller make the system resilient against fluctuations in both wind generation and grid faults. The results highlight the value of GFM-based MTHVDC systems as a dependable option for integrating offshore wind energy into the grid, creating a system with superior stability and efficiency in future large-scale renewable energy systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Grid-forming Control of Offshore Wind through a Diode-Rectifier HVDC System: a 2 GW Case StudyarXiv · 2026
- Analysis and suppression of high-frequency oscillation in wind farm-MMC-HVDC interconnected system considering distribution characteristics of submarine cablesInternational Journal of Electrical Power & Energy Systems · 2026
- Generalized Frequency-Domain Stability Analysis Formulation for Multi-Terminal HVDC SystemsarXiv · 2026
- Frequency Feature Transfer and Coordinated Control Algorithm for Offshore Wind MMC-HVDC Systems Based on DC Voltage FluctuationElectronics · 2026
- Research on hierarchical coordinated variable-gain frequency regulation strategy for wind farm MMC-LCC grid-connected systemInternational Journal of Electrical Power & Energy Systems · 2026
- Active Symmetry Support Control for Grid-Following/Grid-Forming Hybrid Renewable Energy Stations Considering Transient Synchronization StabilitySymmetry · 2026