An Optimal Two-Stage Tuned PIDF + Fuzzy Controller for Enhanced LFC in Hybrid Power Systems
Saif H. Almutairi, Fatih Anayi, Michael Packianather, Mokhtar Shouran
Cardiff University · Institute of Electronics
Key points
From the paper's conclusion- Overall, this study introduces a transformative LFC strategy with high practical viability for modern power networks.
Abstract
Ensuring reliable power system control demands innovative architectural solutions. This research introduces a fault-tolerant hybrid parallel compensator architecture for load frequency control (LFC), combining a Proportional–Integral–Derivative with Filter (PIDF) compensator with a Fuzzy Fractional-Order PI-PD (Fuzzy FOPI–FOPD) module. Particle Swarm Optimization (PSO) determines optimal PID gains, while the Catch Fish Optimization Algorithm (CFOA) tunes the Fuzzy FOPI–FOPD parameters—both minimizing the Integral Time Absolute Error (ITAE) index. The parallel compensator structure guarantees continuous operation during subsystem faults, substantially boosting grid reliability. Rigorous partial failure tests confirm uncompromised performance-controlled degradation. Benchmark comparisons against contemporary controllers reveal the proposed architecture’s superiority, quantifiable through transient metric enhancements: undershoot suppression (−9.57 × 10−5 p.u. to −1.17 × 10−7 p.u.), settling time improvement (8.8000 s to 3.1511 s), and ITAE reduction (0.0007891 to 0.0000001608), verifying precision and stability gains. Resilience analyses across parameter drift and step load scenarios, simulated in MATLAB/Simulink, demonstrate superior disturbance attenuation and operational stability. These outcomes confirm the solution’s robustness, dependability, and field readiness. Overall, this study introduces a transformative LFC strategy with high practical viability for modern power networks.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- An Intelligent Hybrid PIDF Enhanced by a Fuzzy Fractional-Order Controller for Robust Load Frequency Regulation in a Two-Area Interconnected Power SystemEnergies · 2026
- Improvement of combined LFC-AVR system performance with fuzzy PID controller in single and multi-area power networksResults in Engineering · 2025
- Robust hybrid T1/IT2 fuzzy PIDD² controllers for AVR systems under parameter uncertainties and challenging operating conditionsInternational Journal of Systems Science · 2026
- Robust load frequency control in renewable integrated Multi Area grids using hybrid SA and QIO tuned PIDF controllerScientific Reports · 2025
- Comparative Investigation of PID-Derived Cascade Controllers for Frequency Stability Using the Harris Hawks OptimizationComputation · 2026
- Load Frequency Control of Multi-Area Power System Using Hybrid Fuzzy Tilt Integral with Tilt Integral Derivative-Based Fractional Order ControllerAlgorithms · 2026