Robust load frequency control in renewable integrated Multi Area grids using hybrid SA and QIO tuned PIDF controller
W.M. Younis, Muhammad Zubair Yameen, Abdul Khalique Junejo, M. A. Abido, Muhammad Shoaib Khalid
Yanshan University · King Fahd University of Petroleum and Minerals
Key points
From the paper's conclusion- To address this, we propose a hybrid Simulated Annealing-Quadratic Interpolation Optimizer (hsa-QIO)-tuned filtered PID (PID-F) controller for robust load frequency control in two-area grids with wind, photovoltaic (PV), and thermal generation.
Abstract
Frequency stability in renewable-integrated power systems faces critical challenges from load fluctuations, solar/wind intermittency, and nonlinear dynamics. Conventional Proportional-Integral-Derivative (PID) controllers exhibit poor disturbance rejection during concurrent solar irradiance drops and load steps, while optimization algorithms like Genetic Algorithm (GA), Particle Swarm Optimization (PSO), Artificial Neural Network (ANN), and Support Vector Machine (SVM) controllers suffer from premature convergence or computational inefficiency. To address this, we propose a hybrid Simulated Annealing-Quadratic Interpolation Optimizer (hsa-QIO)-tuned filtered PID (PID-F) controller for robust load frequency control in two-area grids with wind, photovoltaic (PV), and thermal generation. The hsa-QIO synergizes global exploration (quadratic interpolation) and probabilistic refinement (simulated annealing), overcoming solution space stagnation. Validated through MATLAB/Simulink simulations under dynamic solar irradiance fluctuations and random load perturbations (0.1-0.4 pu), our approach achieves: 55.7% reduction in Integral Time-weighted Absolute Error (ITAE) versus QIO; 25% lower overshoot (0.9% vs. ANN-PID's 1.2%) and 50% faster settling (0.1 s vs. GA-PID's 0.2 s) in Area 1; superior tie-line regulation (0.3% overshoot/0.4% undershoot vs. SVM's 0.5% and PSO-PID's 0.8%); and statistical robustness with 98.8% lower ITAE deviation (σ = 0.010578) across 30 runs. This computationally efficient solution enables stringent frequency stability (± 0.2 Hz) in high-renewable penetration grids.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Load Frequency Control of Multi-Area Power System Using Hybrid Fuzzy Tilt Integral with Tilt Integral Derivative-Based Fractional Order ControllerAlgorithms · 2026
- Optimal fractional order PID-load frequency controller for multi-interconnected microgrids including renewable energy and storage systemScientific Reports · 2026
- An Intelligent Hybrid PIDF Enhanced by a Fuzzy Fractional-Order Controller for Robust Load Frequency Regulation in a Two-Area Interconnected Power SystemEnergies · 2026
- Load Frequency Regulation for Thermal Units Integrated with Renewable Energy Sources and Energy Storage SystemsEnergies · 2026
- Optimal load frequency control and automatic voltage regulation in four-area interconnected power systems using FOPD-FOPIDD2 controller design with energy valley optimizerScientific Reports · 2026
- Optimal Fractional‐Order PID Control for Multiarea Interconnected Power Systems Using an Adaptive Time‐Varying PSOGSA AlgorithmInternational Transactions on Electrical Energy Systems · 2026