Comparative Investigation of PID-Derived Cascade Controllers for Frequency Stability Using the Harris Hawks Optimization
Alaa A. K. Ismaeel, Mahmoud Abuelneel, Ali M. El-Rifaie, Tamer Mohamed Barakat, Mokhtar Said, Mohamed Barakat
Key points
From the paper's conclusion- These findings show that controller selection should account for system dynamics, disturbance characteristics, robustness, optimization consistency, and controller complexity rather than relying solely on the best objective value.
Abstract
This paper presents a comparative investigation of seven cascade-controller configurations for load frequency control (LFC) in interconnected power systems using the Harris Hawks Optimization (HHO) algorithm. The configurations include PI–PI, PID–PID, PI–PID, PD–PID, PD–PI, PI–PD, and PD–I. Two test systems are considered: a two-area non-reheat thermal power system and a two-area photovoltaic–reheat thermal power system. Controller parameters are optimized for each system to examine the effects of controller structure and system dynamics on frequency regulation. Performance is assessed using the integral of time-weighted absolute error (ITAE), integral of time-weighted squared error (ITSE), and settling time. The investigation covers different load-disturbance scenarios, simultaneous and unequal load changes in both areas, and system parameter variations to evaluate dynamic performance and robustness. Optimization convergence and consistency are also assessed through 20 independent runs for each configuration. In the non-reheat thermal system, PID–PID and PD–PID achieve the lowest ITAE, both reaching 0.02087. In the photovoltaic–reheat thermal system, PID–PID obtains the lowest best-run ITAE of 0.3201, followed by PI–PID at 0.3351. However, the convergence assessment reveals a distinction between best-case performance and repeatability: PID–PID records four failed runs and an ITAE standard deviation of 0.4407, whereas PI–PD has no failed runs and a lower standard deviation of 0.0920. Overall, no controller configuration consistently outperforms the others across all investigated test systems, disturbance scenarios, and performance criteria. These findings show that controller selection should account for system dynamics, disturbance characteristics, robustness, optimization consistency, and controller complexity rather than relying solely on the best objective value. The study provides practical comparative insights and controller-selection guidelines for cascade-based LFC design.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Enhanced FOPID controller for AGC of two-area power system using a Modified Chernobyl Disaster OptimizerThe Journal of Supercomputing · 2026
- A new fractional-order cascade controller structure for frequency regulation of interconnected renewable-dominant power systemsScientific Reports · 2026
- Load Frequency Control of Multi-Area Power System Using Hybrid Fuzzy Tilt Integral with Tilt Integral Derivative-Based Fractional Order ControllerAlgorithms · 2026
- Robust load frequency control in renewable integrated Multi Area grids using hybrid SA and QIO tuned PIDF controllerScientific Reports · 2025
- An Intelligent Hybrid PIDF Enhanced by a Fuzzy Fractional-Order Controller for Robust Load Frequency Regulation in a Two-Area Interconnected Power SystemEnergies · 2026
- Hippopotamus optimization–tuned sigmoid PID controller for load frequency control of a two-area thermal power system with renewable energy sourcesScientific Reports · 2026