Multilayer CaF2 Prism-Coupled Ag/Si3N4/Al2O3 SPR Biosensor for the Early Detection of Carcinoembryonic Antigen Biomarker: A Numerical Approach.
Mujeeb Ur Rehman Laghari, Abdul-Aleem Jamali, Xin-Cheng Ren, Fatima Qureshi, Masood Ali Koondher, Muhammad Rizwan Anjum, Atta Muhammad Panhyar
Department of Electronic Engineering, Quaid-e-Awam University of Engineering, Science and Technology, Nawabshah 67480, Sindh, Pakistan. · Department of Biomedical Engineering, Quaid-e-Awam University of Engineering, Science and Technology, Nawabshah 67480, Sindh, Pakistan.
Key points
From the paper's conclusion- The results demonstrated that the optimized sensor structure achieved stability, with the highest sensitivity reaching up to 361.08°/RIU for different concentrations and the FoM reaching 145.85 RIU−1.
Abstract
The diagnostic tool for the detection of cancer at the initial stage remains the challenging task for the biosensing community, as it requires the detection of a lower concentration (such as <5 ng/mL) of cancer biomarkers, i.e., the carcinoembryonic antigen. For this purpose, the optimization of the multilayered surface plasmon resonance (SPR) nano-sensor configuration is presented in this paper. The optimized sensor comprises the CaF2 prism, silver (Ag), Si3N4, and Al2O3 nanolayers configured in a Kretschmann setup. An electromagnetic analysis is performed to evaluate the performance parameters of the proposed biosensor in CST Studio using the finite integration technique, and the results are also validated through the transfer matrix method. This includes the computation of sensitivity and the figure of merit (FoM). Systematic optimization was performed for the thickness of functional layers. The results demonstrated that the optimized sensor structure achieved stability, with the highest sensitivity reaching up to 361.08°/RIU for different concentrations and the FoM reaching 145.85 RIU-1. It was significant to observe that the optimized configuration remains stable across the full concentration range, while the configuration with thick Si3N4 undergoes a resonance degradation mode at high analyte indices. There is substantial potential of the proposed sensor for biomedical applications such as early-stage detection of lung, colon, liver, and breast cancers.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Performance enhancement of a prism-based label-free SPR biosensor using a Cu/Si3N4/Al2O3 multilayer structure for cancer detection.Nanoscale advances · 2026
- Design and optimization of a hybrid SPR biosensor for highly sensitive detection of carcinoembryonic antigenNext Materials · 2025
- Performance Evaluation of Black Phosphorus and Graphene Layers Using Surface Plasmon Resonance Biosensor for the Detection of CEA AntigensPhotonics · 2025
- Integration of computational optics and machine learning for optimized SPR-based carcinoembryonic antigen detectionBiomedical Optics Express · 2026
- SPR biosensor with a graphene overlayer for carcinoma detectionFrontiers in Bioengineering and Biotechnology · 2026
- High-sensitivity Kretschmann-configured SPR biosensor based on Cu/WS₂ /BP/Ni multilayer with machine learning-assisted optimizationModern Physics Letters B · 2026