High-sensitivity Kretschmann-configured SPR biosensor based on Cu/WS₂ /BP/Ni multilayer with machine learning-assisted optimization
G. Arunachalam, Anand Karuppannan, U Pradeep Kumar, C. Sunitha Ram
Gnanamani College of Technology · Karpagam Academy of Higher Education
Abstract
Early identification and precise quantification of low-concentration protein biomarkers such as C-reactive protein (CRP), prostate-specific antigen (PSA), cardiac troponin, and human epidermal growth factor receptor 2 (HER2) are necessary for the screening and early detection and monitoring of cancer, cardiovascular, and inflammatory diseases. Conventional analytical methods like ELISA, Western blotting, and mass spectrometry typically require long assay times and sophisticated instrumentation, which hinder their use in rapid and portable diagnostic applications. In this paper, we describe a high-sensitivity Kretschmann-configuration surface plasmon resonance (SPR) biosensor, with a Cu/WS 2 /Black phosphorus (BP)/Ni multilayered structure formed on top of a BK7 prism, and illuminated with 633 nm p-polarized light. The use of a copper layer enhances localized SPR and enables strong electromagnetic field confinement at the sensing interface. A thin nickel (Ni) outer layer serves as the sensing interface, enhancing structural stability and modulating the plasmonic response. The WS 2 /BP heterostructure significantly enhances light–matter interaction and strengthens electromagnetic field confinement at the metal–dielectric interface. Numerical optimizations were performed using both the transfer matrix method (TMM) and FEM simulations within COMSOL Multiphysics to evaluate the effect of varying copper layer thicknesses (40–52 nm) on the performance of the SPR sensor. The optimized SPR sensor exhibits a peak angular sensitivity of 401.5 ∘ /RIU, a figure of merit of 784.178 RIU, a signal-to-noise ratio (SNR) of 14.648, and a detection limit of approximately 10 RIU. Additionally, the full width at half maximum (FWHM) of the optimized SPR sensor remains constant at 0.512 ∘, indicating good resonance sharpness and stability. Furthermore, an ML-based regression framework was developed to estimate the optimal WS 2 layer thickness, demonstrating values 0.991 and mean absolute percentage error (MAPE) 1.6% across the evaluated layer thicknesses, which makes the design adaptive and scalable. The proposed multilayer SPR sensor architecture has substantial potential for ultrasensitive screening and early detection of cancer, cardiac proteins, and infectious disease markers, as well as integration into portable lab-on-chip systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Surface Plasmon Resonance Analysis of Cancer‐Related Refractive Index Variations Using a MoTe₂ –Black Phosphorus–Cu Multilayer StructureSurface and Interface Analysis · 2026
- Performance enhancement of a prism-based label-free SPR biosensor using a Cu/Si3N4/Al2O3 multilayer structure for cancer detection.Nanoscale advances · 2026
- Performance Optimization of a Kretschmann‐Configured Multilayer MgO/Ag/HfO 2 /2D‐WS 2 SPR Biosensor for Refractive Index‐Based Cancer Cell Detection: A TMM and FEM ApproachAdvanced Theory and Simulations · 2026
- Performance Evaluation of Black Phosphorus and Graphene Layers Using Surface Plasmon Resonance Biosensor for the Detection of CEA AntigensPhotonics · 2025
- Design and analysis of a bimetallic SPR biosensor with BlueP-WSe2 heterostructure for ultrasensitive cortisol detectionTalanta Open · 2026
- Multilayer CaF2 Prism-Coupled Ag/Si3N4/Al2O3 SPR Biosensor for the Early Detection of Carcinoembryonic Antigen Biomarker: A Numerical Approach.Sensors (Basel, Switzerland) · 2026