Performance enhancement of a prism-based label-free SPR biosensor using a Cu/Si3N4/Al2O3 multilayer structure for cancer detection.
Md Nazmul Islam, Md Tawabur Rahman, Al-Hadith Moon, Md Emon Hasan Sourav, Biswajit Dey, Arnab Saha
Department of Electrical and Electronic Engineering, Khulna University of Engineering & Technology Khulna 9203 Bangladesh tawabur@eee.kuet.ac.bd. · Department of Electrical and Electronic Engineering, Bangladesh Army University of Engineering & Technology Natore 6431 Bangladesh.
Key points
From the paper's conclusion- These results demonstrate the potential of the suggested SPR biosensor for biomedical sensing applications including cancer diagnosis.
Abstract
Surface plasmon resonance (SPR) biosensors are becoming more and more popular in label-free and highly sensitive biomedical sensing. However, they generally suffer from limited sensitivity and poor resonance stability, which restrict their practical biomedical sensing performance. Considering these, a prism-coupled multilayer SPR biosensor with the configuration BK7/Cu/Si3N4/Al2O3/analyte is proposed in this study for cancer cell detection. The sensor design is modeled and analyzed using the transfer matrix method (TMM) and further validated through finite element method (FEM) simulations. The optimized configuration consisting of Cu (50 nm), Si3N4 (10 nm), and Al2O3 (2 nm) achieves a maximum sensitivity of 446.07 deg per RIU with a resonance angle shift of 6.245° for breast cancer detection. The corresponding detection accuracy and quality factor are found to be 0.293 deg-1 and 130.62 RIU-1, respectively. Compared with the conventional BK7/Cu/analyte configuration, the proposed multilayer structure exhibits nearly 2.7 times higher sensitivity. The incorporation of the Si3N4 layer improves electromagnetic field confinement at the sensing interface, which contributes to improved sensor response. Additionally, the Al2O3 layer together with Si3N4 helps suppress Cu oxidation and supports stable resonance characteristics. A fabrication tolerance analysis with ±2% thickness variation shows that the maximum sensitivity deviation remains within 6.97%, indicating good structural robustness. The proposed sensor exhibits good linearity within the refractive index range of 1.360-1.399. The electric field distribution indicates evanescent field penetration into the analyte region with an estimated penetration depth of approximately 174 nm, allowing effective interaction between the sensing medium and the plasmonic field. In addition to breast cancer cells, the proposed sensor also shows promising response for adrenal gland, blood, cervical, and skin cancer cells with sensitivities of 347.14, 281.43, 267.71, and 210.00 deg per RIU, respectively. These results demonstrate the potential of the suggested SPR biosensor for biomedical sensing applications including cancer diagnosis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Surface Plasmon Resonance Analysis of Cancer‐Related Refractive Index Variations Using a MoTe₂ –Black Phosphorus–Cu Multilayer StructureSurface and Interface Analysis · 2026
- Multilayer CaF2 Prism-Coupled Ag/Si3N4/Al2O3 SPR Biosensor for the Early Detection of Carcinoembryonic Antigen Biomarker: A Numerical Approach.Sensors (Basel, Switzerland) · 2026
- Silver Thickness Optimization for Sensitivity Enhancement in a Surface Plasmon Resonance Biosensor for Multi-Cancer Detection.Sensors (Basel, Switzerland) · 2026
- High-sensitivity Kretschmann-configured SPR biosensor based on Cu/WS₂ /BP/Ni multilayer with machine learning-assisted optimizationModern Physics Letters B · 2026
- Design and Simulation of Multilayer SPR Biosensor Based on BK7/Ag/BN/BlueP/WSe 2 /BP for Label‐Free Detection of A549 Lung Cancer CellsAdvanced Theory and Simulations · 2026
- Machine Learning‐Assisted Ag/2D‐Material Heterostructure Surface Plasmon Resonance Biosensor for Label‐Free Detection of Brain Tumor and Cancer CellsAdvanced Photonics Research · 2026