Participant-Level Cross-Fit Ensemble Disagreement for Reliability-Aware Vision-Based Infant Respiratory-Rate Estimation.
Hanbeom Yoon
Department of Digital Health, SAIHST, Sungkyunkwan University, 115 Irwon-ro, Gangnam-gu, Seoul, 06355, Korea (the Republic of).
Key points
From the paper's conclusion- The findings establish an empirical error-ranking association in this small, home-recorded infant benchmark, not calibrated uncertainty, a clinically acceptable RR threshold, or prospective monitoring performance.
Abstract
Contactless video-based respiratory-rate (RR) estimates may be unreliable for individual infant recordings even when overall accuracy is acceptable. We examined whether disagreement among participant-separated models could rank estimation reliability in public AIR-125/AIR-400 data (15 infants, 374 approximately 60-second recordings). For each recording, four eligible models excluded its participant group from training; their mean defined the RR estimate and their sample standard deviation defined ensemble disagreement (ED). EfficientPhys and DeepPhys were the primary architectures, with VIRENet examined as a third-architecture sensitivity analysis. ED was associated with absolute error (Spearman rho 0.742, 0.756, and 0.778, respectively). At 70% retrospective coverage, retained-recording MAE decreased from 3.64 to 2.00, 4.00 to 2.15, and 3.62 to 2.27 breaths/min, respectively, relative to all recordings. Exploratory reanalysis identified exact agreement among all four models in 28.3%-32.9% of recordings, including occasional large errors, and instability at very low coverage. The findings establish an empirical error-ranking association in this small, home-recorded infant benchmark, not calibrated uncertainty, a clinically acceptable RR threshold, or prospective monitoring performance. Independent cohorts with physiological reference measurements and deployment evaluation are needed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Periodicity-Driven Adaptive Localization of Respiratory Regions for Non-Contact Respiration Monitoring in Sleeping Infants.Bioengineering (Basel, Switzerland) · 2026
- Colour-Channel Selection for Video-Based Respiratory Rate Estimation: A Diagnostic Study with a Single-Shot Held-Out Evaluation.Sensors (Basel, Switzerland) · 2026
- DeepRespNet: a hybrid attention-recurrent framework for non-contact respiratory rate estimationFrontiers in Physiology · 2026
- Coverage collapse and deceptive calibration in EEG fatigue monitoring: a cross-dataset audit under within-session and cross-subject shift.Journal of neural engineering · 2026
- Ensemble-based label adjudication (EBLA): A method for validating continuous physiological measures against observer-dependent reference standards.Physiological reports · 2026
- Alert-List Concordance for Evaluating Imputation Strategies in ICU Sepsis PredictionarXiv · 2026