Contact Mapping Using a Low-Cost Velostat Sensor Array in a Synthetic Ankle Model.
Rafael Claramunt, Camilla Laturra, Antonio Ros, Pier Paolo Valentini
Mechanical Engineering Department, ETSI Industriales, Universidad Politécnica de Madrid, C/ José Gutiérrez Abascal, 2-28006 Madrid, Spain. · Enterprise Engineering Department, Università degli Studi di Roma Tor Vergata, Via del Politecnico, 1-00133 Rome, Italy.
Key points
From the paper's conclusion- This study presents a single experimental synthetic model of the human ankle joint—characterized by high-curvature joint surfaces—incorporating ligamentous constraints, a custom Velostat™ piezoresistive 6 × 4 sensor array, and low-cost microcontroller electronics.
Abstract
Estimating joint pressure distribution is crucial for understanding how pathologies disrupt natural biomechanics and for optimizing rehabilitation outcomes. While numerous computational, cadaveric, and "in vivo" studies have investigated joint mechanics, most have focused on the hip and knee, leaving the ankle underrepresented. Flexible matrix sensors offer a compelling solution for intra-articular pressure mapping due to their thin profile and sensing networks. This study presents a single experimental synthetic model of the human ankle joint-characterized by high-curvature joint surfaces-incorporating ligamentous constraints, a custom Velostat™ piezoresistive 6 × 4 sensor array, and low-cost microcontroller electronics. Joint kinematics was evaluated in the sagittal plane across the range of motion from dorsiflexion to plantarflexion in five angular positions under four clinical conditions: intact joint, unreduced posterior malleolar fracture, and fracture fixation using two distinct syndesmotic stabilization techniques. Motion was passively induced without external axial loading to isolate the mechanical contribution of the ligaments. Qualitative intra-articular contact maps revealed distinct differences among surgical approaches. These preliminary results demonstrate the viability of flexible, low-cost piezoresistive sensing systems as a proof of concept for intra-articular contact monitoring in complex anatomical joints.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Flexible sensors for biomechanical monitoring in motion analysis and rehabilitation medicineSensors and Actuators Reports · 2026
- Wireless Instrumented Ankle Foot Orthosis (AFO) for Gait Cycle MonitoringInstruments · 2026
- Multimodal Gait Acquisition and Musculoskeletal Simulation for Subject-Specific Evaluation of Ankle Exosuit Cable Anchor Positioning in Cerebral Palsy.Biomimetics (Basel, Switzerland) · 2026
- A Wearable Pressure-Sensor-Based System for Gait Cycle Analysis: Evaluation and Preliminary Clinical Assessment.Medical engineering & physics · 2026
- Spatial Decoupling of Foot-Substrate Cross-Talk in Plantar Pressure Sensor Arrays.Biomimetics (Basel, Switzerland) · 2026
- Methods for the identification of ankle joint dynamics using a novel sub-malleolar interface.Clinical biomechanics (Bristol, Avon) · 2026