Wireless Instrumented Ankle Foot Orthosis (AFO) for Gait Cycle Monitoring
Soufiane Mahraoui, Mauro Serpelloni
University of Brescia
Key points
From the paper's conclusion- Overall, the results validate the electronic instrumentation and demonstrate reliable system performance, indicating that the proposed instrumented AFO represents a promising platform for objective gait assessment and future clinical applications.
Abstract
Ankle–foot orthoses (AFOs) are widely used in the rehabilitation of patients with neurological or musculoskeletal disorders. However, treatment outcomes may be influenced by incorrect use of the device or by inappropriate orthosis selection. Since many types of AFOs are available, differing in materials, stiffness, and geometry, an objective evaluation tool can support clinical decision-making. This work presents the design, development, and characterization of an instrumented AFO able to quantify relevant gait parameters in an objective way. The proposed device integrates three measurement modalities in a compact wearable structure. Two longitudinal strain gauges estimate ankle plantar- and dorsiflexion angles. Two force-sensitive elements detect foot–ground contact and allow identification of stance and swing phases of the gait cycle. A single inertial measurement unit (IMU) is used to measure lateral shank inclination. The strain-gauge-based angle estimation was validated against a gold-standard motion capture system, achieving a root mean square error of approximately 1.6 degrees and showing higher accuracy than the IMU for plantar/dorsiflexion measurement, while maintaining a simple electronic architecture. The force sensors were validated using a force platform and demonstrated reliable detection of loading and unloading events. Monitoring lateral inclination through the single IMU provides additional information related to balance and potential fall risk. Data are transmitted via Bluetooth Low Energy (BLE) to a custom Python-based application for real-time visualization and recording. Overall, the results validate the electronic instrumentation and demonstrate reliable system performance, indicating that the proposed instrumented AFO represents a promising platform for objective gait assessment and future clinical applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Contact Mapping Using a Low-Cost Velostat Sensor Array in a Synthetic Ankle Model.Sensors (Basel, Switzerland) · 2026
- A Wearable Pressure-Sensor-Based System for Gait Cycle Analysis: Evaluation and Preliminary Clinical Assessment.Medical engineering & physics · 2026
- Methods for measuring the sagittal resistive torque of ankle-foot orthoses during gait: A systematic review.Prosthetics and orthotics international · 2026
- Effects of ankle-foot orthosis stiffness on lower-limb joint work during various movement tasks in people with calf muscle weakness-an explorative study.Frontiers in rehabilitation sciences · 2026
- Ankle-Foot Orthosis and Footwear Interactions in Adult Healthy and Patient Populations: Systematic Review of Biomechanical Outcomes.JMIR rehabilitation and assistive technologies · 2026
- PROST: An Open Toolbox, Harmonised Multi-Lab Dataset, and Meta-Analysis of Ankle-Foot Roll-Over ShapebioRxiv · 2026