A Wearable Pressure-Sensor-Based System for Gait Cycle Analysis: Evaluation and Preliminary Clinical Assessment.
Guan-Jyun Song, Chih-Wei Chang, Chien-Hung Chen, Sung-Pu Liao, Chin-Kai Huang, Jing-Jing Fang
Department of Mechanical Engineering, National Cheng Kung University, No. 1, University Road, East Dist.,, Tainan City, 70101, Taiwan. · Department of Orthopedics, National Cheng Kung University, No. 1, University Road, East Dist.,, Tainan City, 70101, Taiwan.
Key points
From the paper's conclusion- In a preliminary clinical assessment, 21 participants in the control group (C) with Kellgren-Lawrence grades 0-2 and 22 participants in the experimental group (E) with grades 3-4 were evaluated.
Abstract
Gait analysis is commonly used to characterize pathological gait patterns, monitor rehabilitation, and evaluate treatment outcomes. This study evaluated a self-developed, low-cost, portable gait cycle analysis system (GCAS) based on pressure-sensing insoles to measure spatiotemporal gait parameters and plantar center-of-pressure trajectories during walking. The system integrates eight pressure sensors per insole, fuzzy-logic-based gait-phase classification, signal acquisition, and wireless data transmission. Pressure signals were acquired at 100 Hz and classified into four gait phases: heel contact, flat-foot contact, push-off, and swing. To assess measurement consistency, we simultaneously recorded 50 steps for each pairwise comparison of GCAS, AMTI force plate (FP), and Pedar pressure-measuring insole (PMI). GCAS showed lower mean anterior-posterior (AP) trajectory length than PMI and FP, whereas medial-lateral (ML) width showed smaller differences among systems. GCAS also showed lower variability in AP length and ML width than PMI. Bilateral COP analysis showed comparable intersection patterns between GCAS and PMI, with differences of 2.75, 2.51, and 4.10 mm in the horizontal, vertical, and straight-line directions, respectively. In a preliminary clinical assessment, 21 participants in the control group (C) with Kellgren-Lawrence grades 0-2 and 22 participants in the experimental group (E) with grades 3-4 were evaluated. E showed significantly lower walking speed, stride ratio, and HFPS ratio and greater AP variability than C. These findings provide preliminary evidence that GCAS can capture gait characteristics and may support portable assessment of gait abnormalities.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- From Static to Dynamic: Complementary Roles of FSR and Piezoelectric Sensors in Wearable Gait and Pressure MonitoringSensors · 2025
- Flexible Insole with Soft, Integrated, Polymeric Pressure Sensors to Discriminate Different Types of Gaits Using Machine Learning TechniquesTechnologies · 2026
- A Sustainable Natural-Rubber IoT Smart Insole for Remote Body-Load Monitoring: An Observational Gait Comparison in Flexible Flatfoot.Sensors (Basel, Switzerland) · 2026
- Advancements in Smart Wearable 3D printed Insoles for Ground Reaction Force Estimation and Gait AnalysisJournal of Physics: Conference Series · 2026
- Temporal Consistency and Averaging Sensitivity of Released Smart-Insole Gait Summaries in Participants with and without Knee Osteoarthritis.Sensors (Basel, Switzerland) · 2026
- Accelerometer Data Harmonization and Feature Engineering for Gait AnalyticsmedRxiv · 2026