Technical Feasibility of Respiratory Monitoring in Dogs Using Time-of-Flight Depth Imaging.
Oskar Seifert, Marcel Geis, Niklas Alexander Koehler, Manuel Stenger, Volker Groß, Martin Kramer, Keywan Sohrabi
Faculty of Health Sciences, University of Applied Sciences, 35390 Giessen, Germany. · Faculty of Veterinary Medicine, Small Animal Clinic, Justus Liebig University, 35390 Giessen, Germany.
Key points
From the paper's conclusion- These findings demonstrate waveform extraction and dependence on spatial and temporal processing.
Abstract
Time-of-flight (ToF) depth imaging offers contactless observation of respiratory surface motion in veterinary patients. We investigated the technical feasibility of extracting canine respiratory waveforms and explored agreement between recorded camera-derived respiratory rates and concurrent manual counts. Depth images were acquired at a nominal 10 frames/s, and a fixed region of interest (ROI) supplied a mean depth signal. Clinical rates were obtained using Fourier spectral analysis with interpolation. Four dogs contributed eight sessions and 40 paired one-minute observations. Mean bias was +2.33 breaths/min (95% confidence interval -3.60 to +8.25), mean absolute error was 3.93 breaths/min, and exploratory repeated-measures limits of agreement were -10.40 to +15.05 breaths/min. One dog accounted for 69.4% of the absolute error and all observations above 25 breaths/min. Supplementary analyses compared spectral and peak-based estimates on identical inputs. An additional analysis of 27 ROI configurations in each of two recordings from one dog found maximum minute estimate changes of 7.50 and 7.80 breaths/min relative to a fixed baseline ROI. These findings demonstrate waveform extraction and dependence on spatial and temporal processing. They do not establish reliable respiratory rate measurement across dogs or respiratory rate ranges. The small independent sample, heterogeneous errors, incomplete original FFT configuration records and unquantified reference timing constrain the clinical comparison.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Feasibility of Remote Camera-Based Respiratory Motion Detection in Hospitalized Dogs Using the InsectEye Image-Analysis Application: A Pilot Study.Veterinary sciences · 2026
- Tracking Is Not Sensing: Artifact-Aware Thermal Video Respiration Estimation in Head-Free MarmosetsarXiv · 2026
- A Real-Time Low-Cost Platform for Non-Contact Respiratory Rate Monitoring: A Comparative Evaluation of RGB Optical Flow and Time-of-Flight Depth SensingarXiv · 2026
- Contactless Estimation of Respiratory Frequency Using 3D-CNN on Thermal ImagesarXiv · 2026
- Estimation of Respiratory Volumes During Tidal Breathing Using Two Depth Cameras.Sensors (Basel, Switzerland) · 2026
- Colour-Channel Selection for Video-Based Respiratory Rate Estimation: A Diagnostic Study with a Single-Shot Held-Out Evaluation.Sensors (Basel, Switzerland) · 2026