Temperature-Associated SD Card Logging Failures in PurpleAir Monitors: Findings from the Strong Heart Air Study.
Max Ulibarri, James Ross, Whitney Collado, Anna Tillery, Jason Umans, Mary Mohr, Samantha Ishak, Nicole Amodio,
Vagelos College of Physicians and Surgeons, Columbia University Irving Medical Center, New York, NY 10032, USA. · Lamont-Doherty Earth Observatory, Columbia University, New York, NY 10027, USA.
Key points
From the paper's conclusion- Our findings demonstrate temperature-related limitations of PurpleAir monitors when used without WiFi and provide practical guidance for low-cost PM2.5 monitoring in cold climates.
Abstract
Low-cost air quality monitors are increasingly used in environmental health studies. We report the deployment and evaluation of low-cost, fine particulate matter (PM2.5) monitors in an ongoing investigation of air quality and cardiovascular health in three climatologically distinct American Indian communities. Prior to deploying large numbers of PurpleAir monitors for this work, we conducted pilot collocations of ten monitors at each study site to evaluate performance under field conditions. Monitors were configured to store data locally on SD cards rather than upload via WiFi to avoid cloud-based data ownership concerns in partner American Indian communities. During pilot collocations, we observed substantial data loss in colder regions: data recovery was 57% in Oklahoma and 10% in South Dakota, compared with 100% in Arizona. SD card logging commonly failed when ambient temperatures fell to mean (standard deviation) levels of 4.4 (3.2) °C in Oklahoma and 7.7 (2.0) °C in South Dakota. Follow-up outdoor experiments suggested that WiFi connection improves SD card reliability at low temperatures, while controlled 4 °C cold-room experiments confirmed logging failures without WiFi. Our findings demonstrate temperature-related limitations of PurpleAir monitors when used without WiFi and provide practical guidance for low-cost PM2.5 monitoring in cold climates.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Validation of PurpleAir PM2.5 Sensors in Temperate Urban Environments.ACS ES&T air · 2026
- Validation and Correction of PM2.5 Mass Concentrations from Consumer-Grade Personal Exposure and Outdoor Fixed Monitors: A Two-Year Colocation Study in Colorado.ACS environmental Au · 2026
- City-scale calibration of a low-cost PM2.5 network for regulatory-compliant air-quality assessmentPLOS Climate · 2026
- Evaluating and Calibrating Low-Cost Air Quality Sensors in Contrasting Aerosol RegimesAerosol and Air Quality Research · 2026
- Long-Term Field Performance of Sensirion SEN54 and SPS30 Low-Cost Particle Sensors: Seasonal Variability and Correction Using Dew Point Deficit.Sensors (Basel, Switzerland) · 2026
- Airflow, Heat Transfer, and Relative-Humidity Conditioning in the Plantower PMS5003 Sensor and PurpleAir Monitor.Sensors (Basel, Switzerland) · 2026