City-scale calibration of a low-cost PM2.5 network for regulatory-compliant air-quality assessment
Robert Blaga, Nicoleta Stefu, Sneha Gautam, Chang-Hoi Ho
West University of Timişoara · Karunya University
Key points
From the paper's conclusion- This study presents the calibration and performance analysis of a low-cost sensor (LCS) network for monitoring particulate matter with diameters ≤ 2.5 µm (PM 2.5 ) in Bucharest, Romania.
Abstract
This study presents the calibration and performance analysis of a low-cost sensor (LCS) network for monitoring particulate matter with diameters ≤ 2.5 µm (PM 2.5 ) in Bucharest, Romania. The InfoAer network comprised 44 Clarity Node-S sensors deployed across the city. The performance of sensors was evaluated against reference measurements from the National Environmental Protection Agency (NEPA) regulatory monitoring stations. The manufacturer’s pre-calibration significantly underestimated PM 2.5 concentrations, particularly during the summer months, when meteorological conditions favor the formation of secondary aerosols. Nine spatial clusters with collocated InfoAer-NEPA measurements were identified, with one designated for calibration model development and the remaining eight for independent validation. Multiple seasonal calibration models were developed using temperature, relative humidity, and nitrogen dioxide as predictor variables in a multiple linear regression formulation. Calibration performance was compromised during hot, dry conditions, when PM 2.5 concentrations were typically low, likely due to reduced aerosol scattering efficiency and increased measurement uncertainty. Using only temperature and relative humidity as predictors, the optimal model, selected via a two-step calibration process, substantially improved measurement accuracy. Pearson correlation coefficients improved from 0.06 to 0.65 and from −0.28 to 0.89 for the dry and humid seasons, respectively. However, considerable inter-sensor variability in calibration performance was observed, indicating the need for additional meteorological or chemical parameters in future calibration algorithms. Application of the calibration model to the entire InfoAer network revealed significant air quality violations across Bucharest. On average, calibrated sensors recorded more than 60 days of exceedances of the European Union’s daily PM 2.5 limit value (25 μg m −3 ) per year, which far exceeded the permitted frequency of 35 exceedances per year. Prior to calibration, only 8 of 44 sensors (18%) exceeded this threshold; post-calibration analysis revealed violations at all monitoring locations. These results demonstrated the critical importance of proper LCS calibration for accurately assessing regulatory compliance and protecting public health.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluating and Calibrating Low-Cost Air Quality Sensors in Contrasting Aerosol RegimesAerosol and Air Quality Research · 2026
- Calibration of Low-Cost Particulate Matter Sensors for Exposure Assessment: A Critical Review.Current environmental health reports · 2026
- Validation of PurpleAir PM2.5 Sensors in Temperate Urban Environments.ACS ES&T air · 2026
- How Accurate Are Low-Cost Air Quality Sensors? A 10-Month Study of Three-Tier Comparison with Three Calibration Methods and Cross-Site Transferability.Sensors (Basel, Switzerland) · 2026
- A review of machine learning approaches for improving calibration and performance of low-cost air quality sensor networksSensor Review · 2026
- Machine Learning Calibration Transfer for Low-Cost Air Quality Sensors: Distance-Based Uncertainty Quantification in a Hybrid Urban Monitoring NetworkAtmosphere · 2026