Design and Experimental Validation of a Synchronized Multi-Rate Wireless Sensor Network for Multimodal Physiological and Biomechanical Data Acquisition.
Ali Pourhossein, Charmayne M L Hughes
Age-Appropriate Human-Machine Systems, Institute of Psychology and Ergonomics, Technische Universität Berlin, 10623 Berlin, Germany.
Key points
From the paper's conclusion- These results demonstrate the feasibility and reliability of a unified wireless architecture that integrates heterogeneous multi-rate sensing, continuous clock-drift compensation, preservation of original sensor measurements, and comprehensive data-integrity monitoring for synchronized physiological and biomechanical data acquisition.
Abstract
Reliable multimodal measurement requires coordinated acquisition of physiological and biomechanical signals operating at different sampling rates. A six-node wireless architecture was developed to support seven data streams: three surface electromyography (sEMG) signals (2 kHz each), photoplethysmography (PPG, 400 Hz configured), inertial measurements (416 Hz configured), and independent pinch- and grip-force streams (nominal 80-SPS HX711 mode; measured at 85.1 and 85.9 samples/s, respectively). An ESP32-S3 gateway uses a single ESP-NOW network for sensor-data delivery and continuous per-node clock compensation while preserving raw measurements, sample-level timing metadata, and end-to-end integrity diagnostics. Across three independent 30-min full-system recordings, pooled packet delivery and sample continuity were 99.987% and 99.988%, respectively. External common-input validation between two independent sEMG nodes yielded a drift-compensated timing mean absolute error of 0.0754 ms across 897 accepted events. A separate six-node GPIO reference-pulse test yielded a node-clock alignment mean absolute error of 0.3123 ms across 5319 matched events with 99.49% of events below 1 ms. Network-load and indoor distance tests further characterized communication robustness. These results demonstrate the feasibility and reliability of a unified wireless architecture that integrates heterogeneous multi-rate sensing, continuous clock-drift compensation, preservation of original sensor measurements, and comprehensive data-integrity monitoring for synchronized physiological and biomechanical data acquisition.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Deterministic Edge Acquisition of Contextual, Multimodal Physiological Signals: A Bilateral-Ready Dual-Core IoT Biosensing Architecture for Ageing-Focused ResearchElectronics · 2026
- Time and frequency characteristics of various noninvasive heartbeat sensors.PloS one · 2026
- Wireless Motion Monitoring Using a Dual-Node ESP-NOW Architecture for TelerehabilitationApplied Sciences · 2026
- Open Sync Board – An open-source tool for hardware synchronization of multimodal physiological sensor setupsJournal of Open Hardware · 2026
- An ESP32-S3 Multimodal Wearable Sensor Platform with Embedded XGBoost for Focal-to-Bilateral Tonic-Clonic Seizure Detection and IoT Alerting.Sensors (Basel, Switzerland) · 2026
- ESP32-S3-Based Multimodal Wearable for Remote Vital-Sign Acquisition with ECG-to-PPG Pulse-Arrival-Time Tracking and Functional Cloud Triage: An Engineering Proof of Concept.Sensors (Basel, Switzerland) · 2026