Wireless Motion Monitoring Using a Dual-Node ESP-NOW Architecture for Telerehabilitation
Valeska Gatica-Rojas, Cristian Vidal-Silva
Key points
From the paper's conclusion- These results demonstrate reliable dual-node communication, extended active autonomy, and high perceived usability within the evaluated supervised laboratory sample.
Abstract
Accurate postural and kinematic tracking is essential for telerehabilitation and geriatric care. However, existing wearable monitoring systems struggle to balance continuous low-latency transmission, reliable communication, energy autonomy, and multi-node stream aggregation without expensive or complex hardware. This study presents the design, implementation, and cross-generational usability of the Virtual Therapist Platform (VTP), a low-cost motion-monitoring framework based on a dual-node ESP-NOW architecture. The system employs two wearable units (thoracic and lumbar) integrating a Seeed Studio XIAO nRF52840 Sense, an LSM6DS3TR-C IMU, and an ESP32-C3 communication module, transmitting 40-byte inertial packets at 50 packets/s directly at the Data Link Layer to a Beetle ESP32-C6 gateway for real-time avatar updating. Key novelty lies in the empirical integration of lightweight dual-stream packet aggregation, bounded retry policy, full-device energy profiling, and cross-generational validation. In a 30 min continuous dual-node trial (180,000 packets), the system achieved a 99.68% packet-delivery ratio (0.32% packet loss), a mean delivery-confirmation latency of 8.03 ± 1.98 ms, and a stable aggregate throughput of 99.68 ± 0.52 packets/s. Complete unit power profiling demonstrated an active current of 28.6 mA (~35 h continuous operation with a 1000-mAh battery) and a deep-sleep current of 200 µA (~208-day standby estimate). Supervised usability testing across 18 young adults and 25 older adults yielded high median System Usability Scale (SUS) scores of 97.5 (IQR: 95.0–100.0) and 95.0 (IQR: 90.0–97.5), respectively, with high internal consistency (Cronbach’s α = 0.89) and no significant cohort differences (U = 194.5, p = 0.422, |rrb| = 0.136). These results demonstrate reliable dual-node communication, extended active autonomy, and high perceived usability within the evaluated supervised laboratory sample. Network scalability beyond two wearable nodes and long-term operation in domestic environments remain subjects for future validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Design and Experimental Validation of a Synchronized Multi-Rate Wireless Sensor Network for Multimodal Physiological and Biomechanical Data Acquisition.Sensors (Basel, Switzerland) · 2026
- Autonomous Telerehabilitation via Skeletal Motion Prediction and Joint-Level Performance AssessmentarXiv · 2026
- NeuroFusion-Rehab: Cloud-Integrated IoT System for Privacy-Preserving Telerehabilitation Using Remote Monitoring.Sensors (Basel, Switzerland) · 2026
- Development of a digital dual-channel pressure biofeedback unit: a proof-of-concept for clinically driven re-engineering.Journal of medical engineering & technology · 2026
- TeleMultiStream: An Integrated Robot Teleoperation System with Low-Latency Multi-Stream Video FeedbackarXiv · 2026
- A Compressive Neural Telemetry with Address-Event-μPacket Encoding and Duty-Cycling IR-UWB Transmitter.IEEE transactions on microwave theory and techniques · 2026