Deterministic Edge Acquisition of Contextual, Multimodal Physiological Signals: A Bilateral-Ready Dual-Core IoT Biosensing Architecture for Ageing-Focused Research
Suvish, Josiah E. Balota, Priyalakshmi Sheela, Senthilarasu Sundaram
Key points
From the paper's conclusion- We present the Deterministic Embedded Acquisition Platform Biosensing Hub (DeAP-BioHub), a dual-core STM32H755 architecture isolating acquisition from variable-latency subsystems by peripheral ownership.
Abstract
Sensor capability has outpaced the architectures available to integrate it: in near-body multimodal sensing, the binding constraint is no longer whether a variable can be measured, but whether a platform coordinates heterogeneous channels while preserving timing integrity, contextual interpretability, and extensibility. The gap is acute in ageing-focused research, which needs both side-specific comparison and heterogeneous sensing. We present the Deterministic Embedded Acquisition Platform Biosensing Hub (DeAP-BioHub), a dual-core STM32H755 architecture isolating acquisition from variable-latency subsystems by peripheral ownership. A real-time Cortex-M4 domain performs scheduled sensing, timestamping, and record creation, and a bare-metal Cortex-M7 domain carries telemetry, file-system logging, and operator interaction; the two share only a non-cacheable region and hardware semaphores, exchanging fixed 464-byte records with build-time offset assertions. With telemetry and logging active, the environmental channel held its nominal period at 1000.000 ms, at 1 ms timestamp resolution (SD 0.188 ms, n = 452), 96.5% exactly at nominal; the infrared channel’s 0.517% excess traced to that sensor’s own refresh cycle rather than the scheduler, and no storage-synchronization signature was detectable in the four sessions (combined Rayleigh test, p = 0.99). Contextual sensing shares that scheduling, record structure, and timestamp source rather than sitting in metadata: a fingertip registration was summarized descriptively by a first-order approach (τ = 154 s, R2 = 0.997), and a session reading flat on infrared alone stayed diagnosable from the environmental record. Ageing-focused research is the target application: this is laboratory verification of the acquisition substrate, not evaluation in older adults or clinical validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Edge-AI Instrumentation Framework for Multimodal Biometric Sensing in Active Aging Environments.Sensors (Basel, Switzerland) · 2026
- Open Sync Board – An open-source tool for hardware synchronization of multimodal physiological sensor setupsJournal of Open Hardware · 2026
- Design and Experimental Validation of a Synchronized Multi-Rate Wireless Sensor Network for Multimodal Physiological and Biomechanical Data Acquisition.Sensors (Basel, Switzerland) · 2026
- Reusable Modular Wearable Bioelectronics for Low-Carbon Task-Adaptive Health Monitoring.ACS sensors · 2026
- ESP32-S3-Based Multimodal Wearable for Remote Vital-Sign Acquisition with ECG-to-PPG Pulse-Arrival-Time Tracking and Functional Cloud Triage: An Engineering Proof of Concept.Sensors (Basel, Switzerland) · 2026
- Wearable multimodal sensing for geriatric healthcareSoft Science · 2026