A Review on Glial Fibrillary Acidic Protein Biosensors for Point-of-Care Stroke Diagnosis.
Leonor C Caetano, Vânia C Pinto, Susana O Catarino
Center for Microelectromechanical Systems (CMEMS), University of Minho, 4800-058 Guimarães, Portugal.
Key points
From the paper's conclusion- Overall, despite the heterogeneity of the data available in the literature, the reviewed evidence supports the potential utility of GFAP for hyperacute stroke assessment, owing to its rapid elevation following ICH and its ability to differentiate HS from IS and SMs.
Abstract
Stroke is a major cause of mortality and disability worldwide, and rapid differentiation between IS, haemorrhagic stroke (HS), and SMs is essential for timely treatment. This narrative review examines the potential of GFAP as a biomarker for acute stroke diagnosis and evaluates biosensing strategies for its detection, with particular emphasis on PoC and pre-hospital applications, profiting from its coupling with microfluidic technologies. The biological role, temporal kinetics, and diagnostic and prognostic value of GFAP are first discussed in comparison with other stroke biomarkers. The suitability of cerebrospinal fluid (CSF), serum, plasma, whole blood, urine, saliva, and sweat as biological matrices is then assessed. Finally, electrochemical, optical, mechanical, and other biosensor platforms developed for GFAP detection are reviewed in terms of sensing principles, analytical performance, biological matrices, assay duration, and potential clinical applicability. Overall, despite the heterogeneity of the data available in the literature, the reviewed evidence supports the potential utility of GFAP for hyperacute stroke assessment, owing to its rapid elevation following ICH and its ability to differentiate HS from IS and SMs. However, variability in sampling time, analytical methods, biological matrices, and patient populations limits direct comparison between studies. Further development of integrated and multiplexed PoC biosensors, also benefiting from the wide possibilities of advanced microfluidics' technologies, may facilitate rapid and accessible stroke diagnosis and patient stratification.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- B-057 From Plasma to Whole Blood: Validation of GFAP and NFL as Accessible Biomarkers in StrokeClinical Chemistry · 2026
- GFAP as a Biomarker of Stroke Subtype and Brain Tissue Damage in Acute Stroke: A Systematic Review and Meta-AnalysismedRxiv · 2026
- Clinical Utility of Circulating Biomarkers for Diagnosis and Prognosis of Acute Stroke in the Emergency Department: A Narrative Review from Current Evidence to Clinical Implementation.Diagnostics (Basel, Switzerland) · 2026
- Integrating GFAP Testing With Clinical Scores for Prehospital Large Vessel Occlusion Detection in Patients With Acute Stroke (DETECT LVO)Stroke · 2026
- DIAGnosis using NOvel technology for Subtypes In Stroke (DIAGNOSIS study): performance evaluation protocol.BMJ neurology open · 2026
- MEC-BioSense: Material-Encoded Capillary Biointerface for Autonomous Whole-Blood Biomarker Sensing.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026