B-057 From Plasma to Whole Blood: Validation of GFAP and NFL as Accessible Biomarkers in Stroke
Yuting Xue, Xiangyi Liu, Jiajing Wu
Key points
From the paper's conclusion- The diagnostic accuracy for distinguishing hemorrhagic from ischemic stroke was comparable between whole blood and plasma (AUC 0.86 vs.
Abstract
Background Glial Fibrillary Acidic Protein (GFAP) and Neurofilament Light Chain (NfL) are critical blood-based biomarkers for the diagnosis and monitoring of a wide range of central nervous system (CNS) injuries. Current plasma-based assays require centrifugation, which prolongs turnaround time (TAT) and limits utility in emergency settings. Specifically in acute stroke management, rapid differentiation between hemorrhagic and ischemic subtypes is essential, and GFAP/NfL have shown utility in this application. This study aimed to develop and validate a rapid, automated chemiluminescence immunoassay for the direct quantification of GFAP and NfL in whole blood. Methods We used a dual-antibody sandwich chemiluminescence immunoassay to measure GFAP and NfL in blood samples. The assay was optimized for whole blood through reagent formulation adjustments, including the addition of surfactants (0.3% Tween 20 for GFAP, 0.5% Tween 20 for NfL), and implementation of a hematocrit (HCT) correction algorithm. Performance was evaluated in terms of precision, linearity, limit of quantification, and interference. A total of 115 paired whole blood and plasma samples from 78 acute stroke patients were analyzed to assess consistency and diagnostic accuracy. Results The HCT correction algorithm effectively minimized measurement bias across a wide HCT range (35%–55%), improving whole blood accuracy. Precision for GFAP and NfL in whole blood and plasma showed coefficients of variation (CV) below 5% across a broad concentration range. Excellent correlations were observed between whole blood (HCT-corrected) and plasma measurements for both GFAP (R² = 0.990) and NfL (R² = 0.955). Bland-Altman analysis indicated acceptable agreement, with mean biases of -11.96% for GFAP and 18.37% for NfL. The diagnostic accuracy for distinguishing hemorrhagic from ischemic stroke was comparable between whole blood and plasma (AUC 0.86 vs. 0.84, p=0.58). Conclusion The novel whole blood assay provides a rapid, precise, and reliable method for quantifying GFAP and NfL without centrifugation, delivering results within 30 minutes. Its strong concordance with plasma measurements and broad analytical range support its potential to expedite stroke diagnosis and triage in acute care settings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Review on Glial Fibrillary Acidic Protein Biosensors for Point-of-Care Stroke Diagnosis.Sensors (Basel, Switzerland) · 2026
- GFAP as a Biomarker of Stroke Subtype and Brain Tissue Damage in Acute Stroke: A Systematic Review and Meta-AnalysismedRxiv · 2026
- Integrating GFAP Testing With Clinical Scores for Prehospital Large Vessel Occlusion Detection in Patients With Acute Stroke (DETECT LVO)Stroke · 2026
- A-359 Comparison of Whole Blood and Plasma GFAP and UCH-L1 Blood-Based Biomarkers for Screening Patients with Mild Traumatic Brain InjuryClinical Chemistry · 2026
- Biomarkers in Patients With Acute Ischaemic Stroke Undergoing Thrombectomy Compared With Controls: A Pilot StudyActa Anaesthesiologica Scandinavica · 2026
- Concordance Between Capillary Dried Plasma Spot and Venous Plasma Biomarkers in Traumatic Brain Injury: An Analytical Feasibility Pilot StudymedRxiv · 2026