Application of Deep Learning-Based Markerless Pose Estimation in a 3D Exergame System for Knee Osteoarthritis Exercise Management: Development and Preliminary Evaluation.
Xingye Cheng, Xi Gao, Wenqi Liang, Rebecca M Meiring, Yanxin Zhang
School of Exercise, Sport and Rehabilitation Sciences, Faculty of Science, University of Auckland, Auckland 1023, New Zealand.
Key points
From the paper's conclusion- This study described the development and preliminary evaluation of a KOA-specific 3D exergame exercise management system.
Abstract
Home-based exercise management for people with knee osteoarthritis (KOA) is often limited by insufficient movement supervision, individualization, and progression support. This study described the development and preliminary evaluation of a KOA-specific 3D exergame exercise management system. The system combined markerless motion analysis using a conventional RGB camera with biomechanical analysis, concurrent avatar-based guidance, task-specific feedback, adaptive difficulty adjustment, pain monitoring, therapist override, and training records. Exercise tasks addressed lower-limb strength, balance, range of motion, and toe-in or toe-out gait retraining. Five physiotherapists conducted a preliminary evaluation of the prototype through technology-acceptance and usability questionnaires and semi-structured interviews. They reported generally favorable perceptions and identified clinically relevant exercise content, low sensing burden, comprehensive feedback, and training-progress monitoring as potential strengths. Concerns included fall risk during demanding tasks, limited individualization of some parameters, and insufficient safeguards for unsupervised use. Selected TDPT-derived kinematic measures were also compared with synchronized marker-based motion capture using a public dataset comprising 18 squat cycles from six participants. Agreement varied by measure: waveform associations were strong for functional hip flexion, knee flexion, trunk inclination, and frontal-plane hip abduction/adduction, whereas absolute errors ranged from 6.59° to 20.00° and the foot-orientation proxy showed negligible correlation. These findings provide preliminary clinician-informed and task-specific technical evidence for the prototype but do not establish patient usability or clinical effectiveness. Further technical validation, safety refinement, and supervised evaluation with people with KOA are required before routine or independent home use can be considered.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effectiveness of Mobile Exergaming with Sensor-Based Visual Feedback as an Adjunct Therapy for Home-Based Quadriceps Exercise Training in Knee Osteoarthritis: A Prospective Randomized Controlled TrialLife · 2025
- Validation of Single-Camera MediaPipe BlazePose for Knee Joint Angle Measurement Across Multiple Functional Tasks: Concurrent Validity, Interrater Reliability, and Exploratory Test-Retest Reliability Study.JMIR rehabilitation and assistive technologies · 2026
- Comparison of Joint Kinematics and Spatiotemporal Gait Parameters Between Markerless and Marker-Based Motion Capture in a Large Knee Osteoarthritis Cohort.Annals of biomedical engineering · 2026
- From linear to nonlinear gait measures: validity of a multi-view markerless motion capture systembioRxiv · 2026
- Comparative Analysis of Marker-based vs. Marker-less Computer Vision for a Gamified Lower Limb RehabilitationCurrent Directions in Biomedical Engineering · 2026
- A Preliminary Concurrent Validation of a Portable Markerless Motion Capture System Against Three-Dimensional Gait Analysis Following Total Hip and Knee Arthroplasty.Sensors (Basel, Switzerland) · 2026