Validation of Single-Camera MediaPipe BlazePose for Knee Joint Angle Measurement Across Multiple Functional Tasks: Concurrent Validity, Interrater Reliability, and Exploratory Test-Retest Reliability Study.
Xiaotian Yue, YiXuan Gu, Bo Yu
Department of Rehabilitation, School of International Medical Technology, Shanghai Sanda University, 2727 Jinhai Road, Pudong New District, Shanghai, 201209, China.
Key points
From the paper's conclusion- With dynamic measurement available in 177 of 210 observations (84.3%), agreement among retained outputs depended on task, flexion angle, and detection quality. The findings support further feasibility and screening-level evaluation under controlled acquisition with per-recording quality checks; they do not support replacement of clinical goniometry, precise longitudinal decision-making, absolute 3D kinematic accuracy, or generalization to clinical populations or other smartphones.
Abstract
BACKGROUND: Single-camera markerless pose estimation may support accessible knee movement assessment, but performance can depend on task, joint angle, and detection quality, and evidence across complementary measurement properties remains limited. OBJECTIVE: This study aimed to evaluate agreement of MediaPipe BlazePose Heavy knee-flexion estimates with goniometer-set static target positions and with Kinovea 2D video annotation for dynamic tasks, to assess interrater agreement of the Kinovea annotations, and to explore repeated-session performance in a small retest subsample. METHODS: Squat, sit-to-stand, and bilateral single-leg stance tasks were performed by 15 healthy adults during standardized lateral-view smartphone recording. Static knee flexion was assessed at 4 goniometer-set targets (30°, 60°, 90°, and 120°). Native hip-knee-ankle included angles were converted to clinical knee flexion (0° at full extension). Agreement was assessed using the intraclass correlation coefficient (ICC), specifically ICC2,1, signed bias and 95% limits of agreement, mean absolute error (MAE), and root mean square error (RMSE). Primary intervals used participant-cluster bootstrapping, and limits of agreement accounted for repeated measurements. Dynamic primary estimates were conditional on BlazePose target-frame confidence ≥0.3; low-confidence observations were also reported as detection failures and included in an all-output stress test. Four participants returned after 21 days to 29 days (median 25 d) for exploratory repeated-session analyses. RESULTS: Dynamic measurement was available in 177 of 210 observations (84.3%); 33 of 210 observations (15.7%) failed the confidence criterion. Conditional task-specific ICCs were 0.773 (95% CI 0.564 to 0.875; n=71, 15 participants) for squat, 0.632 (95% CI 0.455 to 0.726; n=58, 12 participants) for sit-to-stand, and 0.136 (95% CI -0.078 to 0.482; n=48, 15 participants) for combined single-leg stance. Task-specific availability was present for 71 of 75 observations (95%), 58 of 75 observations (77%), and 48 of 60 observations (80%), respectively. Without the quality gate, squat ICC was 0.428, and RMSE was 25.43°. Static agreement with set targets resulted in an ICC of 0.874 (95% CI 0.770 to 0.953), with RMSE of 15.49° and angle-dependent signed error. Kinovea interrater ICC was 0.999 (95% CI 0.998 to 0.999) overall, which did not establish 3D accuracy. Repeated-session estimates with the 4 participants remained exploratory. CONCLUSIONS: With dynamic measurement available in 177 of 210 observations (84.3%), agreement among retained outputs depended on task, flexion angle, and detection quality. The findings support further feasibility and screening-level evaluation under controlled acquisition with per-recording quality checks; they do not support replacement of clinical goniometry, precise longitudinal decision-making, absolute 3D kinematic accuracy, or generalization to clinical populations or other smartphones.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reliability and Validity of AI-Based Pose Estimation Algorithms for Assessing Lower-Limb Flexibility and Joint Range of Motion.Sensors (Basel, Switzerland) · 2026
- Measurement Boundaries of Single-Camera Markerless Analysis During Early Sprint AccelerationApplied Sciences · 2026
- Accuracy and Reliability of Markerless Human Pose Estimation for Upper Limb Kinematic Analysis Across Full and Partial Range of Motion TasksApplied Sciences · 2026
- Assessment of monocular human pose estimation models for clinical movement analysisScientific Reports · 2025
- Gait assessment using a 2D video-based pose estimation app in comparison to a markerless motion capture system in subjects with osteoarthritis of the knee - a pilot study.Frontiers in bioengineering and biotechnology · 2026
- From linear to nonlinear gait measures: validity of a multi-view markerless motion capture systembioRxiv · 2026