A Preliminary Concurrent Validation of a Portable Markerless Motion Capture System Against Three-Dimensional Gait Analysis Following Total Hip and Knee Arthroplasty.
Mark Abdelnour, Adam Hart, Patrik Abdelnour, Shawn Robbins, Karen Smith, Tanya Capolicchio, Maria Do Carmo Correia De Lima, Michael Tanzer
Surgical and Interventional Sciences, Department of Surgery, McGill University, Montreal, QC H3G 1A4, Canada. · School of Physical and Occupational Therapy, Faculty of Medicine and Health Sciences, McGill University, Montreal, QC H3G 1Y5, Canada.
Key points
From the paper's conclusion- These findings apply to the combined arthroplasty cohort and should not be interpreted as separate THA and TKA cohorts.
Abstract
Three-dimensional gait analysis (3DGA) in patients undergoing total hip and knee arthroplasty (THA and TKA, respectively) is impractical for widespread clinical use. This study evaluated the Azure Kinect, combined with the Motognosis AMSA software (AK-M), for the assessment of selected clinically relevant gait parameters in THA and TKA patients compared with reference 3DGA. Twenty participants (10 THA, 10 TKA) were simultaneously assessed using AK-M and Qualisys 3DGA while walking along an 8 m walkway. Discrete peaks of sixteen bilateral gait parameters were compared using Bland-Altman mean bias and 95% limits of agreement (LOAs), with ICC(3,1) as a complementary measure of relative consistency. Maximum hip kinematics and knee extension demonstrated low mean bias. In contrast, maximum knee flexion, knee range of motion, and step length demonstrated larger mean bias and wider LOAs. Cadence and gait speed demonstrated the lowest bias and narrowest LOAs. ICC(3,1) values ranged from 0.84 to 0.95. AK-M showed parameter-specific agreement with 3DGA, supporting preliminary concurrent validity for simplified assessment of selected discrete gait outcomes. Wider LOAs for other parameters identify areas requiring further technical refinement and clinical interpretation. These findings apply to the combined arthroplasty cohort and should not be interpreted as separate THA and TKA cohorts.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of Joint Kinematics and Spatiotemporal Gait Parameters Between Markerless and Marker-Based Motion Capture in a Large Knee Osteoarthritis Cohort.Annals of biomedical engineering · 2026
- Evaluating the Correlation Between Markerless Gait Analysis and PROM Scores in Hip and Knee Arthroplasty-A Pilot Cross-Sectional Study.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2026
- AI-Enabled Markerless Motion Capture for Gait Analysis and Rehabilitation: A Narrative Review.Bioengineering (Basel, Switzerland) · 2026
- AI-Based Gait Analysis System for Rehabilitation: Usability Evaluation of Human-Technology InteractionJMIR Rehabilitation and Assistive Technologies · 2025
- Inter-system reliability of markerless motion capture in older hip and knee patients during walking.Frontiers in medical technology · 2026