Validation of an Algorithmic Pipeline for Wrist-Worn Devices to Estimate Walking Speed in People with Multiple Long-Term Conditions.
Dimitrios Megaritis, Lisa Alcock, Kirsty Scott, Hugo Hiden, Ioannis Vogiatzis, Silvia Del Din
Faculty of Health and Life Sciences, Northumbria University Newcastle, Newcastle upon Tyne NE1 8ST, UK. · Translational and Clinical Research Institute, Newcastle University, Newcastle upon Tyne NE4 5PL, UK.
Key points
From the paper's conclusion- These findings support wrist-worn devices for objective gait assessment in multimorbid populations, establishing a validated open-source pipeline for real-world deployment.
Abstract
Wrist-worn devices offer a practical means of monitoring gait, yet no validated end-to-end pipeline exists for deriving digital mobility outcomes (DMOs), including cadence, stride length (SL), and walking speed (WS), in people with multiple long-term conditions (MLTC, the coexistence of two or more long-term conditions). This study presents the first modular pipeline for wrist-worn devices for DMO estimation, validated in 45 older adults with MLTC (65-90 years), whose conditions spanned four multimorbidity clusters (cardiometabolic, painful conditions, pulmonary, and cancer), across laboratory tasks, using stereophotogrammetry as the reference. Algorithms were selected independently for each block (gait sequence detection (GSD), initial contact detection (ICD), SL) using novel, fine-tuned, and adaptive versions of established methods developed on an independent cohort. Blocks were first validated independently before being integrated into a pipeline capturing cumulative error propagation. GSD achieved a recall of 0.90. ICD was robust across algorithms, with the best-performing algorithm achieving a recall of 0.76 and precision of 0.82. At the pipeline level, the best-performing pipeline achieved an SL error of 0.14 m with near-zero bias, cadence absolute error of 7.71 steps/min, and WS absolute error of 0.13 m/s. These findings support wrist-worn devices for objective gait assessment in multimorbid populations, establishing a validated open-source pipeline for real-world deployment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Validation of the mobgap analytical pipeline for estimation of digital mobility outcomes from a single wearable device across all-cause dementia and discrete dementia disease subtypesJournal of NeuroEngineering and Rehabilitation · 2026
- Digital assessment of real-world walking in people with impaired mobility: How many hours and days are needed?International Journal of Behavioral Nutrition and Physical Activity · 2025
- Analytical and clinical validation of step counting method in people living with amyotrophic lateral sclerosisScientific Reports · 2025
- Stride-level measurement of gait as an early sensitive marker of disability progression in ambulatory patients with multiple sclerosisEClinicalMedicine · 2026
- A Comparative Review and Benchmarking Evaluation of Step Detection Methods for Longitudinal Gait Assessment.Sensors (Basel, Switzerland) · 2026
- Establishing global standards on wearable technology for measuring mobility in ageing populations: an international consensus exerciseAge and Ageing · 2025