Validation of the mobgap analytical pipeline for estimation of digital mobility outcomes from a single wearable device across all-cause dementia and discrete dementia disease subtypes
Cameron Kirk, Matthew J. Bancroft, Diego Kaski, Lisa Alcock, Brook Galna, Alan Thomas, Lynn Rochester, Silvia Del Din,
Key points
From the paper's conclusion- Conclusion These findings support the technical validity of mobgap for estimating digital mobility outcomes across common and atypical dementia subtypes, and highlight the need for real-world validation to establish its clinical utility.
Abstract
Background Wearable-derived digital mobility outcomes have potential clinical applications in dementia, yet technical validation of analytical pipelines in this population remains limited. This study evaluated the validity of the mobgap pipeline for estimating walking speed, initial contact detection, stride duration, cadence, and stride length across all-cause dementia and discrete subtypes. Methods Eighty-six participants were recruited from two studies (GaitDem: Alzheimer’s Dementia (AD) = 31, Dementia with Lewy-bodies (DLB) = 25, Parkinson’s Dementia (PDD) = 8, Vascular Dementia (VaD) = 6; UCL DMS Atypical: posterior cortical atrophy (PCA) = 16), completing laboratory walking trials validated against an instrumented walkway (GaitDem) or infrared motion capture (DMS Atypical). DMOs were estimated using the mobgap pipeline, optimised for impaired walking. Results Walking speed was estimated with good agreement across all-cause dementia (Intraclass correlation coefficient (ICC) = 0.83, absolute error = 0.12 m/s, relative error = 11.84%), comparable to previous laboratory validations in gait-impaired populations. Cadence showed the strongest performance (ICC = 0.98, absolute error = 1.34 s/m, relative error = 1.24%), while stride length was the most challenging (ICC = 0.77, relative error = 11.85%). Initial contact detection achieved high sensitivity (0.99) but moderate positive predictive value (PPV) (0.85). By subtype, ICC for walking speed ranged from 0.76 (AD) to 0.89 (VaD), with PDD presenting the greatest challenge across most digital mobility outcomes, likely reflecting motor impairment severity rather than dementia subtype. Conclusion These findings support the technical validity of mobgap for estimating digital mobility outcomes across common and atypical dementia subtypes, and highlight the need for real-world validation to establish its clinical utility.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Validation of an Algorithmic Pipeline for Wrist-Worn Devices to Estimate Walking Speed in People with Multiple Long-Term Conditions.Sensors (Basel, Switzerland) · 2026
- The future of clinical trials? Monitoring mobility as an outcome measure in Parkinson's disease: The mobilise-D studyJournal of Parkinson s Disease · 2025
- Establishing global standards on wearable technology for measuring mobility in ageing populations: an international consensus exerciseAge and Ageing · 2025
- The technological frontier in fall management for older adults with dementia: A scoping review of prediction, detection, and prevention systems.PLOS digital health · 2026
- Digital assessment of real-world walking in people with impaired mobility: How many hours and days are needed?International Journal of Behavioral Nutrition and Physical Activity · 2025
- Stride-level measurement of gait as an early sensitive marker of disability progression in ambulatory patients with multiple sclerosisEClinicalMedicine · 2026