Analytical and clinical validation of step counting method in people living with amyotrophic lateral sclerosis
Marcin Strączkiewicz, Katherine M. Burke, Kate Carney, Narghes Calcagno, Sravan Mandepudi, Alan Premasiri, Fernando G. Vieira, James D. Berry
AGH University of Krakow · MGH Institute of Health Professions
Key points
From the paper's conclusion- Our study covered analytical and clinical validation of a step-counting method developed for ankle-worn accelerometers and demonstrated its applicability to pathological gait.
Abstract
Accelerometer-based digital measures offer a scalable and low-burden means of quantifying physical function, but existing processing algorithms may not quantify pathological gait correctly. In people living with amyotrophic lateral sclerosis (ALS), where gait patterns are slow, variable, and asymmetric, validated tools to quantify mobility are urgently needed. We proposed a step-counting algorithm designed for ankle-worn accelerometers that leverage wavelet-based decomposition to quantify heel strikes under heterogeneous gait patterns. We validated this method using five datasets comprising healthy individuals and those with ALS in controlled and semi-controlled activities, and we performed clinical validation in a free-living cohort of 305 people with ALS. We tested our method for accuracy in detecting steps and recognizing walking activity. Reference labels used for analytical validation were obtained from annotated studies or video-based ground truth. Step counting accuracy was assessed using Bland-Altman analysis while clinical validity was evaluated by comparing step counts to gross motor functioning on the ALS Functional Rating Scale-Revised (ALSFRS-R). Walking recognition was robust across walking conditions and body types; sensitivity ranged from 0.94 to 0.98, and specificity exceeded 0.95 across all evaluated datasets. The mean step counting bias was minimal (e.g., 0.44 steps), and the 95% limits of agreement were narrow (LoA = [-5.90, 5.40]) relative to reference standards, including video-annotated ground truth. Clinical validation indicated substantial differences between groups with various levels of gait impairment, e.g., participants who reported "walks with assist" on the ALSFRS-R accumulated a mean of 1283 (95% CI 1063, 1503) steps/day, while those reporting "normal" walking covered 3984 (95% CI 3537, 4432) steps/day. Our study covered analytical and clinical validation of a step-counting method developed for ankle-worn accelerometers and demonstrated its applicability to pathological gait. The method provides accurate quantification of walking activity in controlled and free-living environments, supporting its use as a digital endpoint in ALS research.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The association between at-home exercise digital metrics and ALS disease progression in lower limbsmedRxiv · 2026
- Validation of an Algorithmic Pipeline for Wrist-Worn Devices to Estimate Walking Speed in People with Multiple Long-Term Conditions.Sensors (Basel, Switzerland) · 2026
- A Comparative Review and Benchmarking Evaluation of Step Detection Methods for Longitudinal Gait Assessment.Sensors (Basel, Switzerland) · 2026
- Stride-level measurement of gait as an early sensitive marker of disability progression in ambulatory patients with multiple sclerosisEClinicalMedicine · 2026
- At-home ankle and wrist accelerometry and machine learning capture motor impairment and disease progression in ataxia-telangiectasiamedRxiv · 2026
- Validity of Functional Performance Outcomes and Gait Metrics Measured by Smartphone Application in Patients with Chronic Stroke.Sensors (Basel, Switzerland) · 2026