Smart Cooling-Integrated End Effector for Bone Drilling in Robotic Surgery
Shilpa Pusuluri, Poolan Vivekananda Shanmuganathan
Key points
From the paper's conclusion- This study presents a robotic end effector with a rule-based, temperature-triggered cooling system mounted on a UR5e collaborative robot.
Abstract
Orthopedic surgery plays a crucial role in the treatment of fractures. When a bone breaks, fixation using screws or plates is required to ensure proper healing and stability, and the first step of this procedure is drilling precise pilot holes in the bone. In bone drilling, maintaining the temperature below 47 °C is critical to prevent thermal damage. Conventional cooling methods use continuous coolant flow, which obstructs the surgeon’s visual field. This study presents a robotic end effector with a rule-based, temperature-triggered cooling system mounted on a UR5e collaborative robot. In the first experimental campaign, a single-threshold (44 °C) ON/OFF strategy was evaluated with repeated trials. In response to the limitations identified, the controller was upgraded to (i) a three-level pulse-width-modulated (PWM) coolant law (0/30/50% at <42, 42–46 and ≥46 °C), (ii) automatic suction coupled to coolant activation, and (iii) a force-adaptive spindle-speed law driven by the robot’s wrist force–torque sensor (speed reduction when the thrust-force increase exceeds 19 N). A second campaign of 24 ex vivo femur trials (two drill diameters × three spindle-speed levels × two feed rates × with/without cooling, one hole per condition) showed that temperature-triggered cooling reduced the peak temperature measured by a thermocouple 0.5 mm from the hole from 57.5 ± 9.7 °C to 46.4 ± 3.8 °C (mean paired reduction 11.2 °C, 95% CI 5.5–16.9 °C; paired t(11) = 4.34, p = 0.001), although three of the 12 cooled holes still exceeded 47 °C, while the pumps were active for only 40.3% of the drilling time on average. An integrated suction mechanism removes debris and excess coolant, which is intended to improve visibility at the drilling site (assessed qualitatively in this study); cooling and suction were associated with a lower measured hole-diameter error in the tested samples. The cobot provides six-component wrist force–torque data as well as the position and velocity of the tool synchronously, enabling real-time monitoring of surgical drilling and acquisition of multi-sensor data useful for continuous process improvement. The results are obtained on non-perfused ex vivo bone and should be regarded as a laboratory proof of concept.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Temperature Increase Limitation During Automatic Bone Drilling in Orthopedic Surgery.International journal of medical sciences · 2026
- A novel drill-milling technology for robot-assisted implant osteotomy preparation: simulation and an ex vivovalidation study.Journal of Zhejiang University. Science. B · 2026
- Mechanistic Investigation and Performance Evaluation of Ultrasonic Bone Drilling under Longitudinal-Torsional Coupled Vibration.Medical engineering & physics · 2026
- Force-thermal behaviors and process optimization of ultrasonic vibration-assisted bone drilling for minimally invasive orthopedic surgeryJournal of Materials Research and Technology · 2026
- Clinical outcomes and learning curve of robot-assisted percutaneous cannulated screw fixation for femoral neck fractures.Frontiers in surgery · 2026
- Ex vivo breach detection using electrical conductivity during robotic pedicle drilling in the spinearXiv · 2026