Frontiers in surgery

Clinical outcomes and learning curve of robot-assisted percutaneous cannulated screw fixation for femoral neck fractures.

Hu Gong, Yang Shu, Te Li, Jibin Chen, Fanghui Zhang

Department of Orthopedics, The Sixth Hospital of Wuhan, Affiliated Hospital of Jianghan University, Wuhan, China. · Department of Orthopedics, Combat-Trauma Treatment Center, General Hospital of Central Theater Command, Wuhan, Hubei, China.

Observational · n=61

Key points

From the paper's conclusion
  • Background Robot-assisted cannulated-screw fixation may improve trajectory control and reduce fluoroscopic acquisitions during femoral neck fracture treatment; however, its comparative clinical benefits and early learning curve remain insufficiently characterized.

Abstract

BACKGROUND: Robot-assisted cannulated-screw fixation may improve trajectory control and reduce fluoroscopic acquisitions during femoral neck fracture treatment; however, its comparative clinical benefits and early learning curve remain insufficiently characterized. METHODS: This single-centre retrospective cohort study included 61 patients aged 18-65 years with acute Pauwels type II or III femoral neck fractures treated between January 2023 and January 2025. Twenty-one patients underwent robot-assisted fixation and 40 underwent conventional freehand fixation with three cannulated screws. Perioperative, radiographic, and 12-month clinical outcomes were compared. The learning curve was assessed using Spearman rank correlation, simple linear regression, and mean-centred cumulative sum (CUSUM) analysis. RESULTS: Baseline characteristics were comparable between groups. Compared with conventional freehand fixation, robot-assisted fixation was associated with shorter total operative time., fewer fluoroscopic acquisitions.., and lower intraoperative blood loss… Robot-assisted fixation was associated with more favourable screw-placement parameters and less femoral-neck shortening. Postoperative day-1 pain scores assessed using VAS were lower in the robot-assisted group. HHS values were higher at 1 month and final follow-up. Fracture-healing time and neck-shaft angle did not differ significantly between groups. Only one postoperative complication occurred during follow-up, consisting of screw back-out in one patient in the freehand group; therefore, comparative safety conclusions were not supported. Within the robot-assisted cohort, case number was inversely associated with total operative time, puncture workflow time, and fluoroscopy use. The mean-centred CUSUM trajectories reached sample-specific maxima at cases 7, 6, and 6, respectively, before showing overall downward trajectories. CONCLUSION: Robot-assisted percutaneous cannulated-screw fixation was associated with greater procedural efficiency and more favourable screw-placement parameters than conventional freehand fixation. Statistically significant differences were observed in postoperative pain, HHS, and femoral-neck shortening; however, the clinical importance of these differences remains uncertain. Operative performance improved across the observed sequence of robot-assisted cases, although no validated proficiency threshold could be established from this cohort.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.