Ex vivo breach detection using electrical conductivity during robotic pedicle drilling in the spine
Jorge Andrés Pérez Velásquez, François Teyssere, Thibault Chandanson, Quentin Grimal, Brahim Tamadazte
Key points
From the paper's conclusion- These findings demonstrate the system's ability to detect potentially hazardous events during drilling and to stop the procedure before.
Abstract
Purpose: Pedicle screw placement is technically demanding in scoliosis treatment. High precision is required due to limited visibility, anatomical variability, and the risk of complications. Although robotic systems assist CT-based planning and execution, they still rely on ionizing intraoperative imaging and complex registration. This study proposes robotic pedicle drilling with real-time preventive breach detection using electrical bioimpedance sensing. Methods: We developed a robotic approach combined with a pedicle-drilling tool equipped with a proprioceptive electrical bioimpedance sensor developed by SpineGuard. A real-time detection algorithm was designed to analyze the electrical bioimpedance signal during drilling and identify abrupt changes in conductivity associated with potential breaches towards the spinal canal. The method operates without external devices or sensors. Results: The ex vivo experiments showed that the proposed method prevented breaches in 100 of the 51 drilling cases. These findings demonstrate the system's ability to detect potentially hazardous events during drilling and to stop the procedure before. The ex vivo experiments demonstrated that the proposed method prevented breaches in all 51 drilling cases. Conclusions: This work demonstrates the feasibility of robotic pedicle drilling with electrical bioimpedance sensing for real-time breach prevention. Using only the tool signal, the method eliminates the need for external sensing systems and supports safer pedicle screw placement.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Axial Convergence in Percutaneous Robotic Pedicle Screw Placement: Mixed-Effects Analysis of 1006 ScrewsSpine Open · 2026
- Clamp-based mechanism for in vivo wired electromagnetic sensor fixation enabling multi-day measurementsCurrent Directions in Biomedical Engineering · 2026
- Impact-Based Analysis Method (IBAM) to evaluate the primary stability of the pedicle screw: A proof of conceptarXiv · 2026
- Mitigating lateral sensing blind spots: A dual-segment bronchoscopic robot with a bioinspired skin.Science advances · 2026
- A Hand-Guided Robotic Drill for Vestibular Implant Surgery—Feasibility of Preventing Membranous Labyrinth RuptureJournal of Otolaryngology - Head and Neck Surgery · 2026
- The Woodpecker variable-speed drilling protocol for robot-assisted subaxial cervical pedicle screw placement: technique and a consecutive series of 1027 screws.Journal of robotic surgery · 2026