Frequency-Dependent Surface-Discharge Lifetime and PRPD Failure Signatures of Polyimide Insulation Under High-Frequency Sinusoidal Voltage.
Bei Li, Tianrun Qi, Qingmin Li
School of Engineering, The University of Edinburgh, Edinburgh EH9 3FB, UK. · State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, China.
Key points
From the paper's conclusion- The fitted lifetime relation provides a quantitative planning basis over the tested 10-40 kHz grid for insulation design of high-frequency power equipment, and the finger signature provides a candidate device-level morphological criterion for online monitoring.
Abstract
Polyimide (PI) film is a widely used insulation material in high-frequency power equipment, yet its frequency-lifetime relation and terminal discharge features have rarely been resolved together over a complete ageing trajectory. This paper reports three contributions. First, a condition-specific frequency-lifetime relation for PI surface insulation is presented, in which the discharge inception voltage is frequency-invariant while the flashover voltage and the surface lifetime both fall with frequency. Second, a stage-resolved discharge morphology derived from phase-resolved patterns is proposed, in which a late-stage finger-like cluster serves as a candidate flashover precursor, complemented by a count-aware, time-normalised discharge activity proxy. Third, a space-charge interpretation linking the per-cycle charge injection budget growth at high frequency to the suppressed inter-cycle dissipation, jointly accounting for the lifetime relation and the non-dendritic damage morphology, is presented. The fitted lifetime relation provides a quantitative planning basis over the tested 10-40 kHz grid for insulation design of high-frequency power equipment, and the finger signature provides a candidate device-level morphological criterion for online monitoring.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Flexible UHF Antenna Sensor for Partial Discharge Detection of High-Voltage Cable JointsMeasurement Science and Technology · 2026
- Aggregation-State Tailored Insulation Robustness by Spherulite Size Control in Semicrystalline Poly(vinylidene fluoride) FilmACS Materials Letters · 2025
- Frequency-Dependent Breakdown of Litz-Wire Insulation Under Repetitive Bipolar Square-Wave VoltagesarXiv · 2026
- Research Progress on Polymer Materials in High-Voltage Applications: A ReviewEnergies · 2026
- Extremely Low Humidity and Frequency Dependence of Dielectric Properties of Highly Fluorinated Polyimides in the 10–330 GHz RangeACS Applied Polymer Materials · 2025
- Transient Electric Field Evolution in a 220 kV Cable Joint Under Switching Overvoltage Considering Measured Dielectric DispersionProcesses · 2026