Loop-Mediated Isothermal Amplification (LAMP) Assessment for Malaria Diagnosis in Equatorial Guinea.
Alexandra Martín-Ramírez, Teodora Mikumu Alogo, Victoria Palacios, Monserrat Kobe Elonga, Victoria Mangue, Irene Molina-de la Fuente, Vicenta González Mora, Marta Lanza-Suárez,
Malaria and Emerging Parasites Laboratory, National Center for Microbiology, Institute of Health Carlos III, 28222 Madrid, Spain. · Baney Research Laboratory, Baney P.O. Box 338, Equatorial Guinea.
Key points
From the paper's conclusion- These findings indicate that Dual-LAMP-Pspp and Nested-PCR-Pf are suitable methods for malaria diagnosis in EG.
Abstract
Malaria diagnosis in Equatorial Guinea (EG) is based on conventional microscopy, sometimes combined with rapid diagnostic tests (RDTs). However, some laboratories, such as the Baney Research Laboratory (BRL) have implemented molecular technology for the diagnosis of infectious diseases. This study aimed to evaluate, for the first time in EG, a LAMP method for malaria diagnosis, comparing its performance with conventional microscopy performed in EG and with LAMP and PCR diagnostic methods performed at the National Centre of Tropical Medicine (NCTM), Spain. A total of 178 blood samples (including P. falciparum samples and malaria-negative controls) were evaluated using Dual-LAMP-Pspp and Nested-PCR-Pf in Equatorial Guinea. Dual-LAMP-Pspp performed at the BRL showed sensitivity and specificity values of 97.28% and 100%, respectively, for malaria diagnosis, with no differences between colorimetric and fluorescence-based result readings. Meanwhile, Nested-PCR-Pf showed a sensitivity of 87.07% and a specificity of 100%. Comparison of parasite densities determined by Dual-LAMP-Pspp and conventional microscopy showed a significant moderate negative correlation (correlation coefficient = -0.584). The comparison of Dual-LAMP-Pspp results between BRL and NCTM showed a kappa coefficient of 0.93, whereas the kappa coefficient of the Nested-PCR-Pf assay was 0.70. These findings indicate that Dual-LAMP-Pspp and Nested-PCR-Pf are suitable methods for malaria diagnosis in EG. However, the Dual-LAMP-Pspp assay was easy to perform and interpret and provided results in a shorter time than Nested-PCR-Pf.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Detection of Plasmodium vivax and Plasmodium falciparum using colorimetric loop-mediated isothermal amplification from dried blood spots collected in active and passive malaria surveillance in the Peruvian Amazon.PLoS neglected tropical diseases · 2026
- Field evaluation of a loop-mediated isothermal amplification test for detection of Plasmodium spp. in the Amazonas region of Peru.Current research in parasitology & vector-borne diseases · 2026
- Uracil-DNA Glycosylase-Enhanced Loop-Mediated Isothermal Amplification Assays for Detection of Zoonotic Malaria Plasmodium Parasites.Vector borne and zoonotic diseases (Larchmont, N.Y.) · 2026
- Diagnostic performance of the miLab MAL AI-driven automated digital microscopy system versus standard microscopy for Plasmodium spp. detection.Journal of clinical microbiology · 2026
- Rapid and Femtogram-level Sensitive Detection of Blastocystis spp. Using Colorimetric and Fluorometric LAMP Assays: Analytical and Clinical Validation.Journal of applied microbiology · 2026
- The Fate of the Urine Malaria Test in Malaria Diagnosis: Evaluating its Diagnostic Accuracy in Plasmodium Falciparum Detection in Febrile Children in a Low-resource Country.Nigerian journal of clinical practice · 2026