Current research in parasitology & vector-borne diseases

Field evaluation of a loop-mediated isothermal amplification test for detection of Plasmodium spp. in the Amazonas region of Peru.

Julio Sandoval-Bances, Lucía Rojas-Zúñiga, Rafael Tapia-Limonchi, Hugo O Valdivia, Stella M Chenet, S Pilar Suguimoto

Instituto de Investigación de Enfermedades Tropicales (IET), Universidad Nacional Toribio Rodríguez de Mendoza de Amazonas (UNTRM), Jr. Higos Urco No. 342-350, Chachapoyas, Amazonas, 01001, Peru. · Centro Nacional de Salud Pública (CNSP), Instituto Nacional de Salud (INS), Av. Defensores del Morro 2268, Chorrillos, Lima, 15066, Peru.

Key points

From the paper's conclusion
  • Our findings support its potential as a deployable molecular diagnostic approach in areas with limited access to conventional laboratory infrastructure.

Abstract

Malaria remains a significant public health burden in Peru, particularly in remote endemic areas where access to sensitive diagnostic methods is limited. We evaluated a simplified molecular approach combining Boil and Spin (B&S) DNA extraction with malachite green loop-mediated isothermal amplification (MG-LAMP) for the detection of Plasmodium spp. Under laboratory conditions, 100 Plasmodium spp.-positive and 100 negative samples confirmed by real-time PCR from inhabitants of the Río Santiago District, Amazonas, Peru, were tested with the B&S-MG-LAMP assay. Subsequently, we screened 252 residents from malaria-endemic communities in this area during 2024 as a field evaluation. Standard diagnostic performance measures, including sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and area under the ROC curve (AUC), were calculated using real-time PCR as the reference standard. B&S-MG-LAMP detected one Plasmodium spp. parasite/μl, compared with 2.5 parasites/μl for real-time PCR. In the laboratory evaluation (n = 200), the assay showed 97.0% sensitivity and 100.0% specificity for Plasmodium spp., with 98.5% overall agreement (Cohen's κ = 0.97) with real-time PCR. Sensitivity was 93.6% for P. falciparum and 100% for P. vivax, with 100% specificity for both species. In the field evaluation (n = 252), B&S-MG-LAMP detected 19 positive samples, whereas real-time PCR detected 17, all corresponding to P. vivax. The assay showed 100% sensitivity and 99.1% specificity, with excellent agreement with real-time PCR (Cohen's κ = 0.92; AUC = 0.99). No P. falciparum-positive cases were detected by either method during the field evaluation. The B&S-MG-LAMP assay demonstrated high diagnostic performance for malaria detection in the population studied. Our findings support its potential as a deployable molecular diagnostic approach in areas with limited access to conventional laboratory infrastructure.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers