Detection of Plasmodium vivax and Plasmodium falciparum using colorimetric loop-mediated isothermal amplification from dried blood spots collected in active and passive malaria surveillance in the Peruvian Amazon.
Oscar Nolasco, Joaquín Gómez, Hugo Rodríguez-Ferrucci, Dionicia Gamboa, Christopher Delgado-Ratto
Laboratorio de Malaria: Parásitos y Vectores, Laboratorios de Investigación y Desarrollo, Facultad de Ciencias e Ingeniería, Universidad Peruana Cayetano Heredia, Lima, Peru. · Malaria Research Group (MaRch), Global Health Institute, Family Medicine and Population Health Department, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium.
Key points
From the paper's conclusion- These findings support cLAMP as a practical and sensitive complementary tool for malaria surveillance in low-transmission and elimination settings.
Abstract
BACKGROUND: As malaria transmission declines in regions approaching elimination, highly sensitive diagnostic tools are needed to detect low-density infections, particularly in active and passive surveillance settings. Loop-mediated isothermal amplification (LAMP) is a promising molecular alternative to conventional diagnostics. This study evaluated the performance of a colorimetric LAMP (cLAMP) assay for detecting Plasmodium vivax and Plasmodium falciparum from dried blood spots (DBS) in the Peruvian Amazon. METHODOLOGY/PRINCIPAL FINDINGS: The cLAMP assay was applied to DNA extracted from DBS collected through active case detection (ACD; n = 574) and passive case detection (PCD; n = 431). Two extraction methods were compared: mini spin column (MSC DNA) and a boil-and-spin (BS DNA) method. Diagnostic performance was evaluated against microscopy and real-time quantitative PCR (qPCR). In ACD samples, qPCR identified 125 malaria-positive cases (117 P. vivax, 8 P. falciparum). Microscopy showed a sensitivity of 57.6%, compared with 63.2% for cLAMP using BS DNA and 82.4% using MSC DNA. In PCD samples, qPCR detected 140 positives (129 P. vivax, 9 P. falciparum, and 2 mixed infections). Microscopy sensitivity was 72.9%, while cLAMP reached 77.1% with BS DNA and 82.1% with MSC DNA. Specificity remained high (> 99.0%) across methods. CONCLUSIONS/SIGNIFICANCE: cLAMP improved the detection of malaria infections from DBS compared with microscopy when combined with column-based DNA extraction in active surveillance activities. While the boil-and-spin method showed performance comparable to microscopy, column-based extraction substantially increased sensitivity, especially for low-density infections identified through active surveillance. These findings support cLAMP as a practical and sensitive complementary tool for malaria surveillance in low-transmission and elimination settings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Field evaluation of a loop-mediated isothermal amplification test for detection of Plasmodium spp. in the Amazonas region of Peru.Current research in parasitology & vector-borne diseases · 2026
- Loop-Mediated Isothermal Amplification (LAMP) Assessment for Malaria Diagnosis in Equatorial Guinea.Pathogens (Basel, Switzerland) · 2026
- Magnetic bead-based enhancement of qPCR detection rates in low-density Plasmodium falciparum samples: A comparative analysis of nucleic acid extraction methods.PloS one · 2026
- The underperforming Abbott-Bioline Malaria Ag P.f/P.v rapid diagnostic test: a whiter shade of pale - where the truth is not plain to seeMalaria Journal · 2025
- Underappreciated Transmission of Plasmodium malariae and Plasmodium ovale: A Potential Barrier to Malaria Elimination in Bangladesh.The American journal of tropical medicine and hygiene · 2026
- A PCR-based assay for the sensitive and accurate determination of malaria parasite species that commonly infect humans, including discrimination of Plasmodium ovalecurtisi and Plasmodium ovalewallikeribioRxiv · 2026