Long-Term Environmental Surveillance of Pseudomonas aeruginosa in a Hospital Water Distribution System: Trends in Prevalence, Biofilm Formation, and Antimicrobial Susceptibility.
Maria Luisa Cristina, Elisa Schinca, Carolina Piccinini, Sara Cima, Gianluca Ottria, Chiara Dupont, Alessio Carbone, Marina Sartini
Department of Health Sciences, University of Genoa, 16132 Genoa, Italy. · Department of Medicine, Division of Medical Oncology, Galliera Hospital, 16128 Genoa, Italy.
Key points
From the paper's conclusion- Long-term surveillance integrated within a comprehensive WSP was associated with reduced P. aeruginosa contamination, decreased biofilm-forming ability, and persistently low antimicrobial resistance.
Abstract
BACKGROUND: Hospital water systems are major environmental reservoirs of Pseudomonas aeruginosa, but evidence on the long-term impact of Water Safety Plans (WSPs) on environmental prevalence, antimicrobial resistance, and biofilm-forming ability remains limited. This study evaluated the long-term occurrence of P. aeruginosa in a hospital water distribution system over a 15-year surveillance period. METHODS: A 15-year environmental surveillance study was conducted in a tertiary-care hospital in Northern Italy. Water samples were cultured for P. aeruginosa, and recovered isolates were assessed for antimicrobial susceptibility and biofilm-forming ability. Temporal trends were analysed using generalized linear and segmented logistic regression models. RESULTS: Among 1696 water samples, the overall prevalence of P. aeruginosa was 2.93%, with a significant annual decline of 12% (OR 0.88, 95% CI 0.82-0.94; p < 0.001). Segmented regression identified a marked reduction after the fourth year (OR 0.18, 95% CI 0.06-0.55; p = 0.003). Over time, isolates shifted toward weak or non-biofilm-producing phenotypes while maintaining high antimicrobial susceptibility, with only one multidrug-resistant isolate detected. CONCLUSIONS: Long-term surveillance integrated within a comprehensive WSP was associated with reduced P. aeruginosa contamination, decreased biofilm-forming ability, and persistently low antimicrobial resistance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Narrative Review on the Recent Advances in Pseudomonas aeruginosa Transmission: Focus on Hospital EnvironmentsMicrobiologyOpen · 2026
- Long-term control of Legionella pneumophila and Pseudomonas aeruginosa in dental unit waterlines following optimization of a hypochlorous acid-based water safety program.Frontiers in oral health · 2026
- Longitudinal Antimicrobial Susceptibility Shifts in Environmental Legionella pneumophila from a Drinking Water Distribution System.Pathogens (Basel, Switzerland) · 2026
- Molecular detection of biofilm-related genes and antimicrobial resistance patterns in Pseudomonas aeruginosa isolates from Northern Iran.Journal of applied genetics · 2026
- Utilizing UV LED Disinfection to Decrease Pseudomonas aeruginosa Biofilm Formation in Drinking Water SystemsAWWA Water Science · 2026
- Comparison of antimicrobial resistance patterns of bloodstream Pseudomonas aeruginosa isolates from two tertiary university hospitals in Türkiye and Hungary.Infection, disease & health · 2026