Longitudinal Antimicrobial Susceptibility Shifts in Environmental Legionella pneumophila from a Drinking Water Distribution System.
Lana Madagi, Maya Azrad, May Karp, Avi Peretz, Yehonatan Sharaby
Department of Evolutionary and Environmental Biology, Faculty of Natural Sciences, University of Haifa, Haifa 3498838, Israel. · Clinical Microbiology Laboratory, Tzafon Medical Center, Poriya 1528001, Israel.
Key points
From the paper's conclusion- Here, we compared the antimicrobial susceptibility of 95 environmental L. pneumophila isolates collected in 2013-2014 with those obtained in 2024-2025 from the same sites in a drinking water distribution system (DWDS) using Epsilometer (E-test).
Abstract
Legionella pneumophila (L. pneumophila) persists in engineered water systems and is the causative agent of Legionnaires' disease. Despite its clinical importance, little is known about whether environmental populations are undergoing gradual changes in their antimicrobial susceptibility. Here, we compared the antimicrobial susceptibility of 95 environmental L. pneumophila isolates collected in 2013-2014 with those obtained in 2024-2025 from the same sites in a drinking water distribution system (DWDS) using Epsilometer (E-test). The analyses showed both temporal and spatial variation: Ciprofloxacin activity remained relatively stable, whereas levofloxacin exhibited a broader minimum inhibitory concentration (MIC) range among contemporary isolates, with the minimum inhibitory concentration required to inhibit the growth of 90% of isolates (MIC90) doubling from 0.5 to 1.0 mg/L, suggesting increased variability and the emergence of less susceptible subpopulations. Tigecycline showed a marked site-specific increase in MIC values, with the mean MIC at site D increasing from 0.26 mg/L in the 2013-2014 isolates to 1.86 mg/L in the 2024-2025 isolates, indicating reduced susceptibility at this site. Among macrolides, erythromycin exhibited the lowest MIC values across both isolate collections, whereas azithromycin showed higher MIC values. Moreover, isolates recovered from adjacent sites within the same DWDS exhibited significantly different susceptibility profiles, possibly reflecting the influence of local environmental conditions. These findings emphasize that L. pneumophila susceptibility is not static but is likely shaped by ecological and temporal factors. The study underscores the importance of long-term environmental surveillance to track the evolution of this pathogen and provides new insights into how micro-scale dynamics within water systems can influence antimicrobial susceptibility patterns.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Long-Term Environmental Surveillance of Pseudomonas aeruginosa in a Hospital Water Distribution System: Trends in Prevalence, Biofilm Formation, and Antimicrobial Susceptibility.Pathogens (Basel, Switzerland) · 2026
- Legionella Occurrence in Buildings: Implications of Public Water System Disinfectant and ResidualAWWA Water Science · 2026
- Linezolid Minimum Inhibitory Concentration Creep and Precision Dosing in Older Adults: a longitudinal surveillance and multicentre population pharmacokinetic study.The Journal of infection · 2026
- From Culture to Omics: Laboratory Methods for Environmental Detection of Legionella in Water Systems.Microorganisms · 2026
- Decision Support Tool to Assess Legionella and Mycobacterium avium Complex Risks from Common Indoor Water UsesWater · 2026
- Legionella Detection in Environmental Water Samples Submitted to the Gyeonggi-do Institute of Health and Environment, 2023-2025: Sample-type Differences and the Increasing Contribution of Cooling-tower Water to Positive Samples.Public health weekly report · 2026