A Narrative Review on the Recent Advances in Pseudomonas aeruginosa Transmission: Focus on Hospital Environments
Comfort Danchal Vandu, Michael Ben Okon, Ilemobayo Victor Fasogbon, Angela Mumbua Musyoka, Wusa Makena, Emmanuel O. Ikuomola, Dominic Terkimbi Swase, Ezra Agwu,
Key points
From the paper's conclusion- Environmental reservoirs are critical drivers of P. aeruginosa transmission in hospitals.
Abstract
Pseudomonas aeruginosa is a high‐risk nosocomial pathogen responsible for severe hospital‐acquired infections. Its persistence in hospital environments is supported by biofilm formation, extensive antimicrobial resistance, and the ability to colonize water systems and medical devices. Genomic technologies have enhanced the understanding of its complex transmission routes. A narrative review approach was used to synthesize evidence from 2015 to 2025. Searches across major databases identified studies focused on environmental persistence, biofilms, genomic surveillance, outbreak reports, and infection prevention and control (IPC) strategies. Data were grouped into thematic areas covering pathogen biology, environmental reservoirs, and control approaches. Water distribution systems, including sinks, drains, showers, and wastewater plumbing, emerged as important, setting‐dependent sources of P. aeruginosa transmission. Biofilm‐mediated survival allowed long‐term colonization, resistance‐gene exchange, and recolonization after disinfection. Comparative genomic tools, when combined with epidemiological evidence, supported environmental–patient links in several outbreaks, revealing multiple clones circulating simultaneously. Medical devices such as bronchoscopes and ventilators also served as additional reservoirs when reprocessing practices were inadequate. Outbreaks reported across continents highlighted recurring system‐level gaps: poor plumbing design, limited environmental monitoring, inconsistent hand hygiene, and insufficient antimicrobial stewardship. Successful interventions included targeted plumbing replacement, waterless patient care, enhanced reprocessing protocols, real‐time sequencing, and integrated IPC stewardship programs. Environmental reservoirs are critical drivers of P. aeruginosa transmission in hospitals. Genomic surveillance provides high‐resolution evidence to support transmission hypotheses and timely interventions. Sustainable control requires robust environmental hygiene, engineering improvements, ongoing surveillance, rapid diagnostics, and stewardship, which is particularly vital in low‐resource settings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Genomic and epidemiological identification of Pseudomonas aeruginosa transmission chains and in hospital ICUsGenome biology · 2026
- Interconnected reservoirs of multidrug-resistant bacteria and plasmids within hospital plumbing infrastructurebioRxiv · 2026
- Global high-risk clones and multidrug-resistant serotype strains of Pseudomonas aeruginosa from surgical site infections in low-resource settingsMicrobiology Spectrum · 2025
- How to Adequately Treat Pseudomonas aeruginosa Infections.Seminars in respiratory and critical care medicine · 2026
- Biofilm Formation on Invasive Medical Devices in Adult Intensive Care Units: A Scoping Review of Biomedical and Clinical Evidence.Journal of clinical medicine · 2026
- High-Risk Clones of the Non-Fermenting Gram-Negative Bacilli Pseudomonas aeruginosa and Acinetobacter baumannii in Brazilian Aquatic Environments: A Systematic Review of Clonal Diversity and Antimicrobial ResistancePandemics · 2026