Preanalytical Benchmarks for Solvent-Based GC-MS Profiling of Volatile Organic Compounds in Diabetic Foot Ulcer Swabs.
Muhammad Shehroz, Julie Okiro, Tommy Kyaw-Tun, Seamus Sreenan, Kellie Fortune, Eimear Daly, Emma K Finlay, Aoife Morrin,
School of Biotechnology, DCU Life Sciences Institute (LSI), Dublin City University, Glasnevin, DublinD09 V209, Ireland. · Academic Department of Endocrinology, Connolly Hospital Blanchardstown, DublinD15 X40D, Ireland.
Key points
From the paper's conclusion- We benchmark a controlled solvent-based extraction workflow with direct internal-standard addition for GC–MS profiling of clinical DFU swabs.
Abstract
Gas chromatography-mass spectrometry (GC-MS) is widely applied to wound-associated volatile organic compounds (VOCs), yet the preanalytical steps that govern its sensitivity remain poorly characterized, limiting comparison across studies of diabetic foot ulcer (DFU) infection. We benchmark a controlled solvent-based extraction workflow with direct internal-standard addition for GC-MS profiling of clinical DFU swabs. A six-compound multiclass panel (butanoic acid, 3-methyl-; 1-octen-3-ol; nonanal; 5-hepten-2-one, 6-methyl-; dimethyl disulfide; and heptane) was spiked onto sterile cotton swabs with toluene-d8 as an internal standard (IS). At day 0, diethyl ether (DE) gave the highest IS-normalized response for every analyte (F(2,6) = 12.4-131.0), most markedly for hydrogen-bond-active species. A 50% nitrogen blowdown step produced volatility-dependent enhancement the lowest enrichment in every solvent (1.0-1.9-fold), whereas high-boiling analytes exceeded 2-fold in DE. Frozen storage at -20 °C for 15 days preserved the IS-normalized response within ±20% of day 0 for most analyte-solvent combinations; hexane gave the tightest precision (mean %RSD 2.3-8.0%), whereas DE was poor for heptane (25.7%). Applied to 28 infected DFUs, the workflow returned 13 VOCs meeting combined retention index (|ΔRI| ≤35) and spectral-library (match factor ≥75) criteria, spanning fatty acids, fermentation products, host lipid-peroxidation aldehydes, phenylalanine catabolites, and palmitamide. These class-stratified preanalytical benchmarks provide an analytical baseline against which clinical wound-VOC studies can be designed and compared.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- VOC·BIO Library: An Integrated Platform for Published Aphid GC-MS Evidence, Biological Contexts, Cheminformatics and Exploratory OBP Docking.Insects · 2026
- Stability of Volatile Organic Compounds in Exhaled Breath Samples: Comparative Evaluation of Storage Conditions Using HS-SPME-GC/MS.Molecules (Basel, Switzerland) · 2026
- Exhaled volatile organic compounds analyzed via GC-IMS as non-invasive biomarkers for severity stratification and prognosis prediction in critical illness.Respiratory medicine · 2026
- GC-MS-based volatolomics and machine learning for predicting bloodstain time since deposition.Analytical and bioanalytical chemistry · 2026
- Headspace SPME GC–MS Analysis of Urinary Volatile Organic Compounds (VOCs) for Classification Under Sample-Limited ConditionsMetabolites · 2026
- Diving into decomposition: detection of volatile organic compounds from submerged human remains using thin-film SPME and GC × GC-TOFMS.The Analyst · 2026