Key points
From the paper's conclusion- Furthermore, a readout method based on an 8-shaped receive coil and a circular transmit coil enables a readout distance of approximately 9 cm and enables real-time pressure monitoring with the LC pressure sensor placed in water through 5 cm-thick pork.
Abstract
Pulmonary artery pressure (PAP) monitoring is important for early detection of heart failure progression, but right heart catheterization is an invasive procedure and thus carries risks of bleeding, infection, vascular injury, and cardiac complications. Conversely, noninvasive methods provide indirect assessments and require sophisticated equipment. This paper presents the design and fabrication of a wireless passive LC pressure sensor for implantable pulmonary artery pressure (PAP) monitoring. The sensor comprises a pressure-sensitive capacitor manufactured using standard MEMS processes and anodic bonding technology, as well as a double-layer spiral inductor on a printed circuit board (PCB). The use of electrostatic shielding electrodes avoids the pull-in effect during anodic bonding, achieving a 2 µm spacing between the capacitor plates to enhance pressure sensitivity. In wireless testing, the LC pressure sensor exhibited a sensitivity of -8.7 kHz/mmHg over the 0–100 mmHg range, with a resolution approaching 1 mmHg. Furthermore, a readout method based on an 8-shaped receive coil and a circular transmit coil enables a readout distance of approximately 9 cm and enables real-time pressure monitoring with the LC pressure sensor placed in water through 5 cm-thick pork. This novel LC pressure sensor offers considerable potential for real-time PAP monitoring, thus contributing to the early-stage prediction of heart failure progression in patients.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Review of Non-Invasive Continuous Blood Pressure Measurement: From Flexible Sensing to Intelligent ModelingAI Sensors · 2025
- Breathable Pulse Sensing Wristband With Full‐Module Shape Adaptivity for Machine Learning‐Assisted Continuous Blood Pressure MonitoringAdvanced Functional Materials · 2026
- Iontronic pressure sensor with a wide linearity range for “plug-and-play” fingertip pulse recording and statistical cardiovascular monitoringMaterials Horizons · 2025
- Development of a flexible conductive microneedle-based sensor for non-invasive monitoring of jugular venous pressure in heart failure patientsEuropean Heart Journal · 2026
- High-sensitivity flexible wireless passive LC pressure sensor enabled by a magnetic field-induced ciliary microstructureSmart Materials and Structures · 2026
- A Flexible Capacitive Pressure Sensor with Broad-Range High Sensitivity Based on 3D Porous Ionogel for Wearable Health Monitoring.Micromachines · 2026