Development of a flexible conductive microneedle-based sensor for non-invasive monitoring of jugular venous pressure in heart failure patients
D Nachman, N Bader, O Amir, K Abd Rbo, I Sarkar, A Abu-Ammar, H Kasem
Key points
From the paper's conclusion- Conclusions This work demonstrates the first microneedle-based platform for continuous, non-invasive JVP monitoring.
Abstract
Introduction Jugular venous pressure (JVP) is a key hemodynamic marker for diagnosis and management of heart failure, yet current assessment methods remain subjective or invasive. A flexible microneedle (MN)-based pressure-sensing platform was developed for continuous, non-invasive JVP monitoring by converting venous pulsation–induced skin deformations into measurable electrical signals. Materials and Methods A soft conductive sensing film composed of 12% ethylene glycol–poly(3,4-ethylenedioxythiophene):polystyrene sulfonate/polyvinyl alcohol (EG–PEDOT:PSS/PVA) was fabricated and mechanically characterized. Polycaprolactone (PCL) MN arrays with varying polyethylene glycol (PEG) concentrations were produced to optimize mechanical coupling. Device performance was evaluated using mechanical testing and electromechanical measurements. A pilot clinical study was conducted in patients undergoing right-heart catheterization following institutional ethics approval and acquisition of informed consent. Results and Discussion The EG–PEDOT:PSS/PVA film exhibited low Young’s modulus (E = 0.0078 ± 0.005 MPa) and high stretchability, enabling sensitive detection of small pressure variations. MN arrays containing 1% PEG demonstrated optimal mechanical properties and significantly enhanced strain transfer. The MN-integrated sensor detected physiologically relevant pressures (2–11 mmHg) with ΔR/R₀ responses of 12–46%, whereas a flat sensor without MNs exhibited only 1–4% variation. In the clinical evaluation (n = 5 patients), stable signal segments showed waveform morphology and temporal features closely matching invasive catheter measurements with a coefficient of determination of R2= 0.7767 across subjects, confirming the effectiveness and clinical relevance of MN-mediated surface sensing. Conclusions This work demonstrates the first microneedle-based platform for continuous, non-invasive JVP monitoring. The technology addresses key limitations of existing clinical methods and offers a novel diagnostic pathway for improved heart failure management.Graphical Abstract
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A strain-insensitive multiplexed soft microneedle patch for robust interstitial fluid biomarker monitoringProceedings of the National Academy of Sciences · 2026
- Piezoionic copolymer ionogel with tunable hydrogen bond enables epidermal blood pressure analyzer.Science advances · 2026
- Wireless Passive LC Pressure Sensor for Implantable Hemodynamic Pressure Monitoring with Long Detection DistanceMicromachines · 2026
- Breathable Pulse Sensing Wristband With Full‐Module Shape Adaptivity for Machine Learning‐Assisted Continuous Blood Pressure MonitoringAdvanced Functional Materials · 2026
- Multimodal Wearable Sensor System for Continuous Peripheral Circulation Monitoring in Postoperative Flap Care.Advanced healthcare materials · 2026
- High-Performance Flexible Capacitive Pressure Sensor with an Electrospun Ionic Fiber Membrane as a Dielectric LayerACS Applied Electronic Materials · 2026