A Flexible Capacitive Pressure Sensor with Broad-Range High Sensitivity Based on 3D Porous Ionogel for Wearable Health Monitoring.
Yi Chen, Xuedan Xie, Yonghua Wang, Dan Liu
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Testing Technology and Instrument, North University of China, Taiyuan 030051, China. · Department of Electrical and Control Engineering, Shanxi Institute of Energy, Jinzhong 030600, China.
Key points
From the paper's conclusion- To circumvent the limitations of existing sensors in maintaining high responsiveness across extensive pressure ranges, herein, a novel flexible capacitive pressure sensor is developed based on a 3D porous ionogel foam composite (IL/EG/PVA@MF) coupled with a planar electrode array.
Abstract
Flexible pressure sensors featuring high sensitivity, a broad detection range, and excellent stability are pivotal components for high-precision electronic skins and human health monitoring. To circumvent the limitations of existing sensors in maintaining high responsiveness across extensive pressure ranges, herein, a novel flexible capacitive pressure sensor is developed based on a 3D porous ionogel foam composite (IL/EG/PVA@MF) coupled with a planar electrode array. This device leverages the synergistic structural engineering of the 3D hyperelastic melamine foam (MF) skeleton and the pressure-regulated fringe-field distribution and iontronic interfacial polarization of the porous ionogel. Experimental evaluations demonstrate that the sensor achieves a high normalized sensitivity of 62.45 kPa-1 (2-10 kPa) and maintains reliable piecewise linear sensing performance across a broad working range of 0-50 kPa, accompanied by a rapid response time of within 8 ms. Furthermore, the sensor exhibits outstanding performance consistency after 6000 compression-release cycles at 50 kPa, verifying its good mechanical durability. In practical applications, the device can monitor diverse physiological signals with high fidelity, ranging from subtle radial artery pulses to large-scale joint movements and specific coughing patterns, underscoring its broad potential for integrated wearable systems and intelligent healthcare.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- High-Performance Flexible Capacitive Pressure Sensor with an Electrospun Ionic Fiber Membrane as a Dielectric LayerACS Applied Electronic Materials · 2026
- Ultra-Wide-Range Linear Capacitive Pressure Sensors Enabled by a Micro-Encapsulated Aqueous-Silicone Dielectric Layer.Langmuir : the ACS journal of surfaces and colloids · 2026
- Interlocked Hemispherical-Conical Porous Dielectric Layers for High-Sensitivity and Wide-Range Capacitive Pressure Sensing.ACS applied materials & interfaces · 2026
- High Sensitivity Iontronic Flexible Pressure Sensor Based on Microstructured Electrodes for Wearable DevicesIEEE Instrumentation & Measurement Magazine · 2026
- A Highly Sensitive and Wide-Range Capacitive Flexible Pressure Sensor Based on a Micropyramid Array and Electrostatically Spun Nanofiber Composite Structure.ACS applied materials & interfaces · 2026
- Integrating Multi-Level Micro/Nanostructures to Synergistically Regulate Contact Behavior and Mechanical Deformation for Broad-Range High-Sensitivity Pressure Sensors.ACS applied materials & interfaces · 2026