Radiographic Fractal Dimension and Implant Stability: An Ex Vivo Study of Implant Design and Osteotomy Preparation
Almudena Banegas-Cano, Arturo Sánchez-Pérez, Alfonso Jornet-García, José María Montoya-Carralero, María José Moya-Villaescusa
Key points
From the paper's conclusion- These exploratory findings do not demonstrate procedure-induced structural changes or validate FD as a predictor of implant stability or osseointegration.
Abstract
Background and Objectives: Radiographic fractal dimension (FD) describes image-pattern complexity, but its relationship with immediate implant fixation remains uncertain. This study examined FD before osteotomy preparation and after implant placement in an ex vivo bovine-rib cohort. Materials and Methods: This secondary analysis included 80 blocks, with one implant per block, two implant designs, and four complete preparation protocols (n = 10 per combination). FD was calculated from periapical radiographs using 200 × 50-pixel ROIs. Factorial analyses, baseline-adjusted ANCOVA, and exploratory correlations were performed. Intraobserver reliability was assessed on 32 images measured twice. Results: Baseline FD differed among preparation-protocol groups (p = 0.025). Post-placement differences remained after baseline adjustment for design (p = 0.017) and protocol (p = 0.029), without a significant interaction (p = 0.587). No significant effects on ΔFD were detected for design (p = 0.251), protocol (p = 0.237), or interaction (p = 0.230). Weak nominal correlations of post-placement FD with insertion torque (r = 0.263) and ISQ (r = 0.222) did not retain significance after Holm correction; none of the correlations adjusted for experimental grouping was significant. The absolute-agreement, single-measurement ICC was 0.416 (95% CI, 0.077 to 0.667); matched reanalyses were approximately 0.108 FD units lower than the original values. Conclusions: Adjusted post-placement FD differences were not accompanied by significant between-group effects on ΔFD. Limited reliability, unresolved original-to-repeat disagreement and uncertain ROI correspondence constrain interpretation. These exploratory findings do not demonstrate procedure-induced structural changes or validate FD as a predictor of implant stability or osseointegration.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fractal analysis of peri-implant trabecular bone complexity following transcrestal sinus floor elevation: a retrospective radiographic study.Frontiers in medicine · 2026
- Evaluation of the Effects of Dental Implant Dimension and Design on Primary Implant Stability Using Different Stability Measurement Devices.Journal of clinical medicine · 2026
- Peri-Implant Radiographic Measurements Compared With Intra-Surgical Assessments: Diagnostic Accuracy and Reproducibility.Journal of periodontal research · 2026
- Inter-implant distances below 3 mm: interproximal bone stability up to 10 years with digital and radiographic comparative assessment of implant spacingInternational Journal of Implant Dentistry · 2026
- Longitudinal Fractal Analysis of Alveolar Trabecular Bone After Non-Surgical Periodontal TreatmentJournal of Functional Biomaterials · 2026
- Interimplant distance and angulation measurement from CAD-generated multiunit abutment interfaces: A scan body-independent technique.The Journal of prosthetic dentistry · 2026