Frontiers in medicine

Fractal analysis of peri-implant trabecular bone complexity following transcrestal sinus floor elevation: a retrospective radiographic study.

Irfan Ustundag, Sevval Ilkyaz, Numan Dedeoglu, Selman Bolukbasi, Mehmet Sait Simsek, Yunus Çetiner, Bahadir Sancar

Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Inonu University, Malatya, Turkiye. · Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Inonu University, Malatya, Turkiye.

Observational · n=35

Key points

From the paper's conclusion
  • No statistically significant between-group differences in peri-implant trabecular bone structural complexity were detected among the 3 mm, 4 mm, and 5 mm TSFE groups over 12 months. These preliminary findings do not establish equivalence and require prospective confirmation; the transient distal change in the 3 mm group should be interpreted cautiously as a region-specific, hypothesis-generating observation.

Abstract

BACKGROUND: This retrospective radiographic study aimed to evaluate time- and region-dependent changes in peri-implant trabecular bone structural complexity using fractal dimension analysis after transcrestal sinus floor elevation (TSFE) with 3, 4, or 5 mm sinus membrane elevation. METHODS: A total of 45 dental implants placed simultaneously with TSFE in 35 patients were categorized into three groups according to sinus membrane elevation height (3 mm, 4 mm, and 5 mm). Fractal dimension analysis was performed using ImageJ software on panoramic radiographs obtained at baseline and at 6 and 12 months postoperatively, in the apical, mesial, and distal peri-implant regions. RESULTS: No statistically significant difference was found among the 3 mm, 4 mm, and 5 mm groups in fractal dimension changes from baseline to 6 or 12 months postoperatively (P > 0.05). In the 4 mm and 5 mm groups, no statistically significant temporal FD changes were detected in any region (P > 0.05). In the 3 mm group, the distal fractal dimension value at 6 months was significantly lower than the apical value (P = 0.006), whereas a significant increase was observed in the distal region between 6 and 12 months (P = 0.013). CONCLUSION: No statistically significant between-group differences in peri-implant trabecular bone structural complexity were detected among the 3 mm, 4 mm, and 5 mm TSFE groups over 12 months. These preliminary findings do not establish equivalence and require prospective confirmation; the transient distal change in the 3 mm group should be interpreted cautiously as a region-specific, hypothesis-generating observation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Fractal analysis of peri-implant trabecular bone complexity following transcrestal sinus floor elevation: a retrospective radiographic study — Science Skim