Usability and Technology Acceptance of a Wearable Monitoring System Among Patients with Cardiovascular Diseases: A Cross-Sectional Study.
Marian Morenci, Diana Carina Iovanovici, Carmen Delia Cseppento Nistor, Sebastian Tirla, Anett Jolán Karetka, Rareș Gheorghe Mihuț, Akos Tiboldi, Lisa Lichtenegger,
Doctoral School of Biomedical Sciences, Faculty of Medicine and Pharmacy, University of Oradea, 410087 Oradea, Romania. · Timișoara Institute of Cardiovascular Diseases, 300310 Timișoara, Romania.
Key points
From the paper's conclusion- These findings support the integration of wearable monitoring systems into routine cardiovascular care and highlight the importance of patient-centered implementation strategies to promote long-term engagement.
Abstract
Background and Objectives: Wearable health technologies have become increasingly important in the remote management of cardiovascular diseases (CVDs); however, their successful implementation depends not only on technical performance but also on patient usability and technology acceptance. This study aimed to evaluate the perceived usability and technology acceptance of a wearable monitoring system among patients with CVDs and to investigate whether demographic and clinical characteristics influenced these outcomes. Materials and Methods: A cross-sectional observational study was conducted among 60 patients with CVDs enrolled in a six-month wearable monitoring program at the Medical Rehabilitation Outpatient Clinic of the Avram Iancu Clinical Hospital, Oradea, Romania. Participants used a Garmin vívosmart® 5 fitness tracker to continuously monitor physiological and behavioral parameters. At the end of the monitoring period, perceived ease of use (PEU) was assessed using the System Usability Scale (SUS), while technology acceptance was evaluated using a Technology Acceptance Model (TAM)-based questionnaire. Descriptive statistics, reliability analysis, Spearman's rank correlation, and multiple linear regression analyses were performed. Results: The wearable monitoring system demonstrated high PEU, with a median SUS score of 82.5 (IQR = 23.1) and a mean score of 75.5 ± 17.6. Overall, 75.0% of participants rated the system as having good or excellent usability. The SUS questionnaire demonstrated acceptable internal consistency (Cronbach's α = 0.730; McDonald's ω = 0.741). Technology acceptance was generally favorable, with an overall median TAM-based score of 1.33 (IQR = 0.78). Age and comorbidity burden were not associated with PEU, and no participant characteristics independently predicted SUS scores. Although the overall regression model was not statistically significant, age showed a statistically significant association with the overall TAM-based score (β = 0.328, p = 0.037). Significant positive correlations were observed between PU, self-efficacy (SE), and reverse-scored technology anxiety (TA) measure (p < 0.001). Conclusions: Patients with CVDs reported high PEU and favorable acceptance of wearable monitoring technology. While usability appeared independent of demographic and clinical characteristics, technology acceptance showed an exploratory association with age, although the overall regression model was not statistically significant. These findings support the integration of wearable monitoring systems into routine cardiovascular care and highlight the importance of patient-centered implementation strategies to promote long-term engagement.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Patient acceptance of continuous wearable vital-sign monitoring on surgical wards: A prospective mixed-methods survey study.PloS one · 2026
- State-of-the-art wearable sensors for cardiovascular health: a reviewnpj Cardiovascular Health · 2025
- Wearable Sensors and Remote Patient Monitoring in Cardiovascular Disease: From Continuous Physiological Surveillance to Actionable Insights.Arteriosclerosis, thrombosis, and vascular biology · 2026
- Cross‐Cultural Adaptation and Psychometric Validation of the Arabic User Satisfaction Evaluation Questionnaire (USEQ)Advances in Human-Computer Interaction · 2026
- Development and validation of an integrated wearable system for continuous cardiorespiratory monitoring using photoplethysmography and optical respiratory detection.Medical & biological engineering & computing · 2026
- Real-World Health Monitoring Using Wrist-Worn Wearables in Community-Dwelling Older Adults in China: Mixed Methods Feasibility Study.JMIR human factors · 2026