PloS one

Patient acceptance of continuous wearable vital-sign monitoring on surgical wards: A prospective mixed-methods survey study.

Ephrahim E Jerry, Daphne L J Nabben, Ashley J R De Bie Dekker, Igor W F Paulussen, R Arthur Bouwman, Simon W Nienhuijs

Department of Surgery, Catharina Hospital Eindhoven, Eindhoven, The Netherlands. · Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.

Observational · n=102

Key points

From the paper's conclusion
  • Patients in this single-center cohort generally reported favorable experiences with continuous wearable vital-sign monitoring. Acceptance differed between the two monitoring contexts, but the study design does not allow these differences to be attributed to a causal effect of device type. Further studies should validate the questionnaire and evaluate clinical effectiveness, safety, cost-effectiveness, and longer-term implementation outcomes.

Abstract

BACKGROUND: Continuous wearable monitoring of vital signs is increasingly implemented on hospital wards to enable early detection of clinical deterioration and to reduce the burden of intermittent vital-sign measurements. While feasibility of wearable monitoring and its acceptance among healthcare professionals have been demonstrated, patient perspectives remain underexplored. OBJECTIVE: To evaluate patient experiences with wearable monitoring devices during hospitalization. METHODS: This prospective, single-center mixed-methods study included adult surgical ward patients monitored with a wearable device (Healthdot or viQtor) for ≥ 24 hours. Patients completed 15 five-point Likert items assessing patient experience and a separate overall satisfaction rating on a 1-10 scale. Qualitative material comprised free-text responses from 36 of the 102 participants and two additional semistructured interviews with participants from the same cohort. Quantitative data were analyzed using descriptive statistics, reliability analysis, exploratory monitoring-context comparisons, and multivariable regression. Qualitative data were analyzed using Braun and Clarke's thematic-analysis approach. RESULTS: A total of 102 patients were included in the final analysis after exclusion of two duplicate questionnaire records. Mean overall acceptance was 4.05 ± 0.54 on a 1-5 scale (95% CI 3.94-4.15), and mean satisfaction was 8.21 ± 1.39 on a 1-10 scale (95% CI 7.93-8.48). Acceptance was higher in the Healthdot context than in the viQtor context, with an exploratory mean difference of 0.40 points (95% CI 0.18-0.62). Qualitative findings indicated generally limited burden, but also concerns regarding comfort and patient information. CONCLUSIONS: Patients in this single-center cohort generally reported favorable experiences with continuous wearable vital-sign monitoring. Acceptance differed between the two monitoring contexts, but the study design does not allow these differences to be attributed to a causal effect of device type. Further studies should validate the questionnaire and evaluate clinical effectiveness, safety, cost-effectiveness, and longer-term implementation outcomes.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Patient acceptance of continuous wearable vital-sign monitoring on surgical wards: A prospective mixed-methods survey study — Science Skim