Application of Numerical Methods for Monitoring the Technical Condition of Cable Post-Tensioned Concrete Girders and Their Constituent Materials.
Tadeusz Chyży, Czesław Miedziałowski, Krzysztof Robert Czech, Marcin Orłowski, Dai Wang, Hai Zhang, Jacek Karpiesiuk
Department of Building Structures and Structural Mechanics, Faculty of Civil Engineering and Environmental Sciences, Bialystok University of Technology, Wiejska 45E, 15-351 Bialystok, Poland. · Department of Construction and Landscaping, Faculty of Civil Engineering and Environmental Sciences, Bialystok University of Technology, Wiejska 45E, 15-351 Bialystok, Poland.
Key points
From the paper's conclusion- The results indicate that long-term monitoring of girder deflections can provide valuable information on changes in prestressing cable condition, provided that thermal effects are simultaneously monitored and accounted for when interpreting the measurements.
Abstract
Cable post-tensioned concrete roof girders constructed in Poland from the 1950s to the 1970s remain in service despite concerns regarding the long-term durability of their prestressing cables. This study investigated the feasibility of using deflection monitoring supported by numerical modeling as an indirect diagnostic method for assessing the technical condition of cable post-tensioned concrete girders. A finite element model of a 24 m span KBOS-24 cable post-tensioned concrete girder assembled from precast segments was developed and verified against in situ tachymetric measurements performed on existing girders in operating industrial facilities. Numerical simulations were conducted to evaluate the effects of complete loss of prestressing force in individual cables and thermal actions on girder deflection. Complete loss of prestressing force in one cable increased the deflection by approximately 2.5-4.0 mm. Temperature differences between the top and bottom chords produced deflections of comparable magnitude, reaching approximately 4.5 mm under the observed service conditions. The results indicate that long-term monitoring of girder deflections can provide valuable information on changes in prestressing cable condition, provided that thermal effects are simultaneously monitored and accounted for when interpreting the measurements.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Coupled Environmental–Mechanical Deterioration Modeling of Prestressed Concrete Beams Under Freeze–Thaw and Corrosion ActionsConstruction Materials · 2026
- Lessons from time-dependent deflection in record span prestressed concrete bridgesScientific Reports · 2025
- Analysis of the shear deformation in simply supported prestressed concrete girder-bridgesProcedia Structural Integrity · 2026
- A Prestress Loss Inverse Analysis Method for Long-Span PC Girder Bridges Combining Finite Element Analysis and Machine LearningEngineering Research Express · 2026
- Deflection monitoring of discontinuous built-up beams using FBG measurements with mechanics-guided regularization.Optics express · 2026
- Investigation of the Causes of Web Cracking and Strengthening Methods for Continuous Box-Girder Bridges with Large Cantilevers and Thin WebBuildings · 2026